VISTA-128BPT/
VISTA-250BPT/
VISTA-128BPTSIA
Commercial Burglary
Partitioned Security System
With Scheduling
User Guide
800-06905 6/10 Rev C
TABLE OF CONTENTS
SYSTEM OVERVIEW ....................................5
Common Lobby Operation .......................25
How User Codes Affect the Common
Lobby........................................................26
CHECKING FOR OPEN ZONES.................27
General.......................................................5
A Partitioned System ..................................6
Zones..........................................................6
Fire Protection ............................................6
Carbon Monoxide Protection......................6
Alarms.........................................................6
Burglary Protection .....................................7
Memory of Alarm ........................................7
Speed Key (Macros)...................................8
Using Schedules.........................................8
Device Timers.............................................8
To Access another Partition (GOTO
Using the ✳ READY Key ......................27
DISPLAYING ALL ZONE
DESCRIPTORS........................................28
Using the ✳ READY Key ......................28
BYPASSING PROTECTION ZONES ..........29
Using the 6 BYPASS Key....................29
Quick Bypass............................................30
Viewing Bypassed Zones .........................30
Group Bypass...........................................31
Zones Remaining Bypassed After
Command)..................................................8
Master Keypad Operation...........................8
Self-Help Feature........................................9
Phone Access & Voice Response
Disarming..................................................32
ARMING PERIMETER ONLY......................33
(WITH ENTRY DELAY ON) .........................33
Capability....................................................9
ABOUT THE KEYPADS...............................10
General.....................................................10
The Alpha Keypad ....................................10
FUNCTIONS OF THE KEYPAD ..................11
ENTRY/EXIT DELAYS.................................14
General Information..................................14
SECURITY CODES AND AUTHORITY
Using the 3 STAY key..........................33
Auto-STAY Arming ...................................34
ARMING PERIMETER ONLY......................35
(WITH ENTRY DELAY OFF) .......................35
Using the 7 INSTANT Key...................35
ARMING ALL PROTECTION.......................36
Using the 2 AWAY Key........................36
LEVELS ....................................................15
General Information..................................15
Duress Code.............................................15
Quick Arming ............................................15
Installer Code Lockout..............................15
Authority Levels ........................................16
General Rules on Authority Levels and
Using the 4 MAXIMUM Key.................37
QUICK EXIT.................................................38
Using the # + 9 Keys.......................38
DISARMING AND SILENCING ALARMS....39
Using the 1 OFF Key ...........................39
Changes ...................................................17
To Exit User Edit Mode.............................17
To Add a User...........................................18
To Change a User's Code ........................20
To Delete a User.......................................21
ACCESSING OTHER PARTITIONS............22
To Access another Partition .....................22
Global Arming...........................................22
Master Keypad Operation.........................23
Memory of Alarm ......................................39
USING THE KEYSWITCH ...........................40
General.....................................................40
Arming ......................................................40
Disarming..................................................40
CHIME MODE..............................................41
– 3 –
TESTING THE SYSTEM (TO BE
Using the 9 Key ...................................41
CONDUCTED WEEKLY) .........................60
VIEWING ALARM COMPANY
Using the 5 TEST Key.........................60
MESSAGES .............................................42
General Information..................................42
PANIC KEYS................................................43
(FOR MANUALLY ACTIVATING SILENT
AND/OR AUDIBLE ALARMS)..................43
Using Panic Keys .....................................43
SPEED KEY (MACROS) .............................44
General Information..................................44
Defining ....................................................44
Executing..................................................45
ACCESS DOOR CONTROL........................46
General Information..................................46
Executing..................................................46
USING #70 RELAY MENU MODE ..............47
General Information..................................47
USING SCHEDULES...................................48
Delaying the Closing Time .......................48
Temporary Open/Close Schedules ..........48
Programming Temporary Schedules .......49
PROGRAMMING DEVICE TIMERS............51
General Information..................................51
Randomize Output Device Times.............53
USING #77 INSTANT ACTIVATION
Testing Your System................................60
FIRE ALARM SYSTEM................................61
In Case Of Fire Alarm...............................61
Silencing a Fire Alarm ..............................61
TROUBLE CONDITIONS ............................62
Typical Trouble Displays ..........................62
Power Failure ...........................................63
RECOMMENDATIONS FOR PROPER
PROTECTION..........................................64
Recommendations for Smoke and
Heat Detectors .........................................64
Recommendations for Proper Intrusion
Protection .................................................65
EMERGENCY EVACUATION .....................66
MAINTAINING YOUR SYSTEM ..................67
Taking Care of Your System ....................67
Replacing Batteries in Wireless
Sensors ....................................................67
Silencing Low Battery Warning Tones
at the Keypad ...........................................68
Routine Care ............................................68
QUICK GUIDE TO SYSTEM
MODE.......................................................54
EVENT LOG PROCEDURES......................57
General Information..................................57
To Display the Event Log .........................57
SETTING THE TIME AND DATE ................59
FUNCTIONS.............................................69
SUMMARY OF AUDIBLE
NOTIFICATION ........................................71
(ALPHA DISPLAY KEYPADS).....................71
INDEX ..........................................................76
– 4 –
System Overview
General
Your Honeywell security system consists of a main control panel, at least one keypad,
and various sensors strategically positioned throughout the premises. The system
offers you three forms of protection: burglary, fire and emergency. The keypad
provides full control of system operation.
The system uses microcomputer technology to monitor all protection zones and
system status and provides appropriate information for display on the keypad(s) used
with the system, and initiates appropriate alarms. Your system may also have been
programmed to automatically transmit alarm or status messages over the phone lines
to a central alarm monitoring station.
This manual is designed to help you become comfortable operating your
system. Each function is explained in step-by-step detail. We recommend you
read the SYSTEM OVERVIEW section to become familiar with the
terminology and the basic features of the system.
NOTE: If you have a Graphic/Touch-Screen Keypad connected to your
system, refer to the Graphic/Touch-Screen Keypad User Guide for operating
instructions.
NOTE: All references in this manual for number of zones, number of user
codes, number of access cards, and the event log capacity, use the VISTA-
250BPT’s features. The following table lists the differences between the
VISTA-128BPT/VISTA-128BPTSIA and the VISTA-250BPT control panels.
Additionally, only the VISTA-128BPT/VISTA-128BPTSIA supports the
capability to have a device duplicate keypad sounds at a remote location. All
other features are identical for both panels.
VISTA-128BPT/VISTA-
Feature
VISTA-250BPT
128BPTSIA
Number of Zones
128
150
250
512
8
250
250
500
1000
15
Number of User Codes
Number of Access Cards
Event Log Capacity
VistaKey Modules
– 5 –
System Overview (cont’d)
A Partitioned System
Simply stated, a partitioned system shares one physical alarm system among
different users, each with their own requirements. For the most part, you as a user
need not know about other users and their structure in the system, but from time to
time, you may see display messages that indicate the system is in use by another
user. Do not be concerned, this is normal. Refer to the ACCESSING OTHER
PARTITIONS section for additional information.
Zones
Your system's sensing devices have been assigned to various "zones." For example,
the sensing device on your Entry/Exit door may have been assigned to zone 001,
sensing devices on windows in the master bedroom to zone 002, and so on. These
numbers will appear on the display, along with an alpha descriptor for that zone (if
programmed), when a fault, alarm or trouble condition occurs.
Fire Protection
The fire protection portion of your security system (if used) is always on and will
sound an alarm if a fire condition is detected. Refer to the FIRE ALARM SYSTEM
section for important information concerning fire protection, smoke detectors and
planning emergency exit routes from your house.
Carbon Monoxide Protection
Carbon monoxide (CO) protection is available with your system using the 5800CO
Carbon Monoxide Detector. The 5800CO is a 3V battery powered wireless Carbon
Monoxide Detector used with wireless alarm systems that support 5800 series
devices. Carbon monoxide gas is a highly poisonous gas which is released when fuels
are burned. It is invisible, has no smell and is therefore impossible to detect with the
human senses. We strongly suggest installing Carbon monoxide protection with your
system.
Alarms
When an alarm occurs, both the keypad and external sounders will sound, and the
keypad will display the zone(s) causing the alarm. If your system is connected to a
central monitoring station, an alarm message will also be sent. To stop the alarm
sounding, simply disarm the system.
The Swinger Suppression feature of your system limits the number of times a non-fire
zone locally annunciates and transmits an alarm report to the central station. Ask
your installer if this feature has been programmed.
– 6 –
System Overview (cont’d)
NOTE: Cross Zoning and Swinger Suppression options can help reduce false alarms.
Ask your installer if your system is programmed for either of these features. An Abort
Window feature exists for all non-fire zones. All non-fire alarm reports are NOT
transmitted to the central station if the code + off sequence is entered within the
Abort Window time period. Ask your installer if this feature has been programmed.
There is also a 5-minute Cancel Window feature in your system. Starting at the end
of the Abort Window you can cancel an alarm. A cancel signal is transmitted if either
the alarm system is disarmed or both a disarm and a function key is pressed during
the 5-minute Cancel Window time-period. A message of alarm aborted will appear on
the keypad screen if this condition occurs.
Burglary Protection
The burglary protection portion of your system must be turned on or "armed" before it
will sense burglary alarm conditions. Your system provides four modes of burglary
protection: STAY, AWAY, INSTANT and MAXIMUM, and even allows you to
BYPASS selected zones of protection while leaving the rest of the system armed. The
system also provides a CHIME mode, for alerting users to the opening and closing of
doors and windows while the system is disarmed. Refer to the other sections of this
manual for procedures for using these features.
The following table lists the four different arming modes and the results of each.
Features For Each Arming Mode
Exit
Delay
Yes
Yes
Yes
Entry
Delay
Yes
Yes
No
Perimeter
Armed
Yes
Arming
Mode
AWAY
STAY*
INSTANT*
MAXIMUM
Yes
Yes
Yes
Yes
No
* The system provides three different STAY and INSTANT arming modes. See
ARMING IN THE STAY MODES and ARMING IN THE INSTANT MODES
sections for details on these modes.
Memory of Alarm
When an alarm condition occurs, the keypad displays the number(s) of the zone(s)
that caused the problem, and displays the type of alarm (ex. FIRE, ALARM). It
remains displayed until it is cleared by disarming the system (see DISARMING THE
SYSTEM section).
– 7 –
System Overview (cont’d)
Speed Key (Macros)
The system can store a string of up to 32 keystrokes, which can be activated anytime
by simply pressing the “A, B, C, or D” keys. This feature can be used to make it easy
to perform multiple functions at once (such as going to another partition to bypass a
zone), or it can be used to simplify an everyday, repeated procedure. Refer to the
SPEED KEY section for procedures for using this feature.
Using Schedules
Your system may have been programmed with schedules for automatically arming,
disarming and activating various devices and/or performing other system functions at
predetermined times. Users can modify some of these schedules by manually delaying
a closing time, using temporary schedules, or by programming special user schedules.
Refer to the USING SCHEDULES section at the end of this manual for scheduling
related procedures.
Device Timers
The system provides up to 20 "timers" that can be used to control various devices,
such as lights or appliances. These timers are similar in concept to the individual
appliance timers that might be purchased at a department store. The devices that can
be controlled are programmed into the system by the installer. Up to 96 of these
devices can be programmed. Refer to the PROGRAMMING DEVICE TIMERS section
for procedures.
To Access another Partition (GOTO Command)
Each keypad is assigned a default partition for display purposes, and will show only
that partition's information. But, if the user is authorized, a keypad in one partition
can be used to perform system functions in another partition, by using the GOTO
command. Note that only those partitions authorized and programmed by the
installer can be accessed in this manner.
To GOTO another partition, enter your security code, then press [∗] followed by the
desired partition number (1-8).
The keypad will remain in the new partition until directed to go to another partition,
or until 2 minutes has elapsed with no keypad activity. Entering your security code,
pressing [∗] followed by [0] will return the keypad to its original partition.
Master Keypad Operation
A "Master" keypad is one on which the status of all eight partitions is displayed
simultaneously. A user can get more information about a certain partition by simply
entering [∗] + the desired partition number (1-8). To log on to the "Master" partition
(9) using the GOTO command, and to perform any functions at a Master keypad, a
user must have access to all partitions.
– 8 –
System Overview (cont’d)
Self-Help Feature
Abbreviated user's instructions are built into the system that can be easily viewed on
the alpha keypad's message display screen. This feature will prove particularly useful
if this manual is not conveniently accessible when you need to perform a system
procedure with which you are not familiar.
To view the abbreviated instructions:
Simply press and hold down the function key of interest until the description starts to
appear (about 5 seconds) and then release it. The system must be “READY TO ARM”
to perform this function.
Refer to the FUNCTIONS OF THE KEYPAD section for descriptions of each key
function.
Phone Access & Voice Response Capability
Your system may include a 4286 VIP module that will permit you to access the system
via a Touch-tone phone, either on-premises or by call-in when away. The phone access
feature will enable you to do the following:
•
•
•
Receive synthesized voice messages over the telephone regarding the status of the
security system.
Arm and disarm the system and perform most function commands via the
telephone, with voice confirmation provided after each command entry.
Control 4204 relay devices and lights and appliances through the #70 Manual
Relay Activation mode.
Complete information regarding the use of this feature is provided in a separate
manual entitled PHONE ACCESS USER GUIDE, which accompanies the 4286 VIP
module.
– 9 –
About The Keypads
General
IMPORTANT: If the keypad beeps rapidly upon entering the
premises, it indicates that an alarm has occurred during your
absence. LEAVE IMMEDIATELY and CONTACT THE POLICE
from a safe location nearby.
NOTE: If you have a Touch Screen Keypad connected to your system, refer
to the Touch Screen Keypad User Guide for operating instructions.
Your keypads allow you to control all system functions. The keypads feature a
telephone style (digital) keypad and a Liquid Crystal Display (LCD) that shows the
nature and location of all occurrences. Keypad display back lighting is programmable
to always stay on or to light only when a key is pressed, then turn off a few minutes
later.
The keypads also feature a built-in sounder that will sound during alarms and
troubles. It will also "beep" during certain system functions, such as during entry/exit
delay times, during CHIME mode, and when depressing keys to perform system
functions (to acknowledge the key press). These sounds can be optionally suppressed
in some of your keypads (so as not to disturb other users of the system). Ask your
installer if this has been done.
The Alpha Keypad
Alpha keypads feature a 2-line, 32 character alphanumeric Liquid Crystal Display
(LCD) that can display system messages in user-friendly English. Abbreviated user's
instructions can also be displayed (see Self Help paragraph in the SYSTEM
OVERVIEW section). These keypads can also be programmed with custom zone
descriptors.
– 10 –
Functions of the Keypad
LCD
DISPLAY
SPEAKER
LEDS
ARMED
READY
OFF
MAX
AWAY
TEST
CODE
STAY
BYPASS
CHIME
1
4
7
2
5
8
0
3
6
9
#
A
B
C
INSTANT
READY
D
FUNCTION
KEYS
IMPORTANT! When using the keypad to enter codes and commands,
sequential key depressions must be made within 3 seconds of one
another. If 3 seconds elapses without a key depression, the entry is
aborted and must be repeated from its beginning.
– 11 –
Functions of the Keypad (cont’d)
PERIMETER ONLY for a full explanation
of the STAY key.
ALPHA DISPLAY WINDOW: A 2-line,
32-character Liquid Crystal Display (LCD)
that displays protection point identification
and system status, messages, and user
instructions.
4 MAXIMUM : Arms in manner similar
to AWAY mode, but eliminates the entry
delay period, thus providing maximum
Disarms the burglary portion of
the system, silences alarms and
1 OFF
protection.
An
alarm
will
occur
immediately upon opening any protection
point, including entry delay zones.
audible trouble indicators, and clears
visual alarm trouble after the problem has
been corrected.
5 TEST : Tests the system and alarm
sounder if disarmed.
2 AWAY :
Completely arms both
perimeter and interior burglary protection
by sensing an intruder's movements
through protected interior areas as well as
guarding protected doors, windows, etc.
Late arrivals can enter through an entry
delay zone without causing an alarm if the
system is disarmed before the entry delay
time expires.
6 BYPASS :
Removes
individual
protection zones from being monitored by
the system. Displays previously bypassed
protection zones.
7 INSTANT : Arms in manner similar
to STAY mode, but turns off the entry
delay period, offering greater security
while inside and not expecting any late
arrivals. An alarm will occur immediately
upon opening any perimeter protection
point, including entry delay zones.
3 STAY : Arms the perimeter burglary
protection, guarding protected doors,
windows and other perimeter protection
points, and sounds an alarm if one is
opened. Also allows automatic bypassing of
certain areas which permits movement
within your house without causing an
alarm. Late arrivals can enter through an
entry delay zone without causing an alarm
if the system is disarmed before the entry
8 CODE : Allows the entry of additional
user codes that can be given to other users
of the system.
delay
time
expires.
See ARMING
– 12 –
Functions of the Keypad (cont’d)
KEYS 0-9: Used to enter your individual
security access code(s).
9 CHIME : Turns on & off the CHIME
mode. When on, any entry through a
protected delay or perimeter zone while the
system is disarmed will cause a tone to
sound at the Keypad(s).
LED READY INDICATOR: (GREEN) Lit
indicates system is ready to be armed,
while unlit indicates system not ready.
LED ARMED INDICATOR: (RED) Lit
when the system has been armed (STAY,
AWAY, INSTANT or MAXIMUM).
SPEAKER: Source of audible internal
warning and confirmation sounds, as well
as alarms (see "Summary of Audible
Notifications").
FUNCTION KEYS: These keys can be
used for Speedkey (macros) functions or
panic keys. Refer to the SPEEDKEY
(MACROS) and PANIC KEYS sections for
descriptions of these functions.
∗ READY : When depressed prior to
arming the system, the keypad will display
all open protection zones within the
keypad's home partition. This key is also
used to display all zone descriptors that
have been programmed for your system, by
holding the key down for at least 5 seconds.
# : Permits ARMING of the system
without use of a security code ("Quick
Arm", if programmed).
–13 –
Entry/Exit Delays
General Information
Your system has installer-programmed time delays, known as exit delay and
entry delay. Whenever you arm your system, exit delay gives you time to
leave through the designated exit door without setting off an alarm. Exit
delay begins immediately after entering any arming command, and applies to
all modes of arming protection. If programmed, a slow beeping will sound
throughout the exit delay period.
Entry Delay gives you time to disarm the system when you reenter through
the designated entrance door. But the system must be disarmed before the
entry delay period ends, or an alarm will occur. The keypad will beep during
the entry delay period, reminding you to disarm the system. You can also
arm the system with no entry delay at all by using either INSTANT or
MAXIMUM arming modes. These modes provide greater security while on
the premises or while away for extended periods of time. See your installer
for your delay times.
As a requirement of SIA-CP-01, Entry Delay is defaulted to a delay of 30
seconds and Exit Delay is defaulted to a delay of 60 seconds.
As a requirement of SIA-CP-01, an Exit Delay Reset is designed to allow a
user to re-enter the premises to retrieve a forgotten item without triggering
an alarm. This feature may only be activated once after arming.
If enabled, when the panel is armed, the normal exit delay begins. After the
user exits, closes the door and then re-enters the premises, the exit delay
time is reset to the programmed value.
As a requirement of SIA-CP-01, there is a communicator delay of 30 seconds
in this control panel. This delay will prevent a report to the central station if
the control panel is disarmed within 30 seconds after an intrusion alarm is
triggered. This delay can be removed, or it can be increased up to 45 seconds
at the option of the user by consulting with the Installer. Note that fire-type
alarms are normally reported without delay.
– 14 –
Security Codes and Authority Levels
General Information
At the time of installation, you were assigned an authority level and a
personal four-digit security code, known only to you and yours. The security
code must be entered when arming and disarming the system. The authority
level defines the system functions that you can perform.
As an additional safety feature, other users that do not have a need to know
your code can be assigned different security codes, and each user can be given
a different authority level. Users are identified by "user numbers", which are
assigned when assigning a user's security code.
All codes can be used interchangeably when performing system functions
within the limits of each code's authority level (a system armed with one
user's code can be disarmed by another user's code), with the exception of the
Operator Level C code. See AUTHORITY LEVELS on the following page for
details regarding authority levels.
Duress Code
This feature is intended for use if you are forced to disarm or arm the system
under threat. When used, the system will act normally, but can silently
notify the central station of your situation, if that service has been provided.
The duress code is pre-assigned by the installer during installation (authority
level 6).
Important: This code is useful only when the system is connected to a
central station.
Quick Arming
Note that if "Quick Arming" was programmed by the installer, the
#
key
can be pressed in place of the security code when arming the system. The
security code must always be used to disarm the system, however.
Installer Code Lockout
If the Installer Code Lockout option has been enabled, the installer may
enter the program mode only for a period of 24 hours. Once the 24-hour
period has expired the installer can only enter the program mode if the
Master user first enters the code + #65. This opens another 24-hour window
in which the installer may enter program mode.
– 15 –
Security Codes and Authority Levels (cont’d)
Authority Levels
Authority levels define the system functions a particular user can perform.
Depending on the authority assigned to you, there are certain system
functions you may be prohibited from performing. In summary, there are six
authority levels, each having certain system restrictions as shown below.
Level 1 Master:
Can perform all system functions in assigned
partitions, and can add, delete or change Manager
and Operator level users. Master codes are added
by the Installer.
Level 2 Manager:
Can perform system functions in assigned
partitions, and can add, delete or change Operator
level users.
Level 3 Operator A:
Level 4 Operator B:
Level 5 Operator C:
Can perform system functions in assigned
partitions, but cannot add or delete other users.
Same as Operator A, except Operator B cannot
bypass zones of protection.
Can arm the system in assigned partitions, but
cannot disarm the system unless the system was
armed with this code. This code is typically
assigned to someone who has
a
need to
arm/disarm the system only at certain times (such
as a baby-sitter).
Level 6 Duress:
Can arm and disarm the system, but also sends a
silent panic alarm to the central station, if that
service is connected.
To view your authority level and system capabilities:
1. Enter your code + ∗ + ∗ .
2. The keypad will display the partition(s) that you are authorized to
operate, and your user number and authority level in each partition.
– 16 –
Security Codes and Authority Levels (cont’d)
General Rules on Authority Levels and Changes
•
A user may not delete or change the user code of the SAME or HIGHER
authority than which he is assigned.
•
•
A user may only ADD users to a LOWER authority level.
A user may assign access codes only to those partitions to which the user
adding the code has access. (Ex. a user with access to only partition 1
cannot assign codes in partition 2.)
•
The only way to assign a user's authority level is by using the "Add a
User" procedure. To change a user's authority level, that user must first
be deleted, and then added again.
•
•
A user can only be DELETED or CHANGED from within the partition he
is assigned.
User numbers must be entered as 3-digit entries. Single digit user
numbers must be preceded by a "00" (example, 003, 004, etc.). Security
codes are entered as 4-digit numbers.
•
Before assigning a security code, be sure it does not conflict with any
DURESS code.
Note: When adding, changing or deleting users, all other alpha keypads in
that partition will display "User Edit Mode – Please Stand By", and key
depressions (except Panic) at those keypads will be ignored. Panic key
depressions will cause an alarm and terminate user entry.
To Exit User Edit Mode
You can exit any of the user edit modes described on the following pages at
any time by doing the following:
1. Press either ∗ or # , or don't press any key for 10 seconds.
2. System returns to normal mode.
– 17 –
Security Codes and Authority Levels (cont’d)
To Add a User
IMPORTANT: Temporary users should not be shown how to use any system
function they do not need to know (e.g. bypassing protection zones).
CODE
1. Enter Master or Manager code and press the
8
key.
2. Enter the new user's 3-digit User Number (002-250).
3. Enter 4-digit security code for that user. The following prompts will
appear.
Enter 1 to add a new user code. Entering 0 will
change the existing user's code to the code entered
in step 3. See Changing A User's Code section.
ADD NEW USER?
0 = NO , 1 = YES
Enter the authority level, 1-6, for this user within
this partition.
USER NUMBER = 003
ENTER AUTH. LEVEL
1=master
2=manager
3=operator A
6=duress code
4=operator B
5=operator C
Enter 1 (YES) to allow this user to perform group
bypasses. Enter 0 (NO) this user will not be able to
perform group bypasses.
GROUP BYPASSING?
0 = NO , 1 = YES
If access schedules have been programmed, this
prompt appears. Enter the user's access group
number (1-8) if this user should have limited
access to the system. Enter 0 if no access group
should be assigned.
ACCESS GROUP?
ENTER 0-8
This prompt will appear if a 5800 series button
transmitter has been supplied and has not yet been
assigned to a user. Press 1 if a button transmitter
will be assigned to this user. Otherwise press 0.
RF BUTTON ?
0 = NO , 1 = YES
If assigning a button transmitter, this prompt will
appear. Enter the button's zone number (see your
installer for zone number).
ENTER BUTTON ZN #
(001-250)
– 18 –
Security Codes and Authority Levels (cont’d)
If you as a user have access to other partitions, the
keypad will prompt for ability of this new user to
access (GOTO) those partitions. Press 0 (NO) or 1
(YES). If no, the system activates this user code and
exits “Add a User” mode. If yes, the keypad prompts
for the Global Arm option for this user.
MULTI-ACCESS ?
0 = NO , 1 = YES
Press 1 (YES) if this user will be allowed to try to
arm more than one partition at the same time.
Press 0 if this user will arm only his assigned
partition.
GLOBAL ARM ?
0 = NO , 1 = YES
The keypad now prompts for the user’s access to the
next partition (see GOTO command). Again press 0
or 1. If yes, the system will automatically assign a
user number for use in that partition and will
prompt for authority level and global arm options
for this user within the partition (see previous
steps).
PART.2 - SHOP?
0 = NO , 1 = YES
When all partitions have been displayed, the
keypad will scroll through the partition(s) to which
access has been assigned, and will display the user
number, authority level and global arm option for
each. The “G” after the authority level indicates
that the global arm feature is active for this user in
the displayed partition. The "*" indicates the
partition from which this user can be changed or
deleted. The "." at the end of the second line
indicates that this user sends open/close reports.
Open/close reporting is automatically active for any
users added by you, if you have open/close reporting
active.
PART. 1 A0* WHSE
USER 003 AUTH=3G.
– 19 –
Security Codes and Authority Levels (cont’d)
To Change a User's Code
CODE
1. Enter Master or Manager code and press the
8
key + user number
to be changed.
2. Enter the new code for that user.
The system will recognize that the user number is
already in use and will prompt whether or not this
is a new user. Enter 0 to change the existing
user's code to the code entered in step 3.
The system will confirm that the change is allowed
based on authorization level, and if so, will put the
new code into effect.
ADD NEW USER?
0 = NO , 1 = YES
USER 002 CHANGED
SUCCESSFULLY
Note that if changing one’s own code, the
system will prompt for the new code to be re-
entered. This prevents accidentally changing one's
own code.
– 20 –
Security Codes and Authority Levels (cont’d)
To Delete a User
CODE
1. Enter Master or Manager code and press the
8
key + user number
to be deleted.
2. Enter Master or Manager code first entered.
The system will recognize that the User number
is already in use and will prompt to confirm that
it should be deleted. Press 0 (NO) or 1 (YES).
If yes, that user's code will be removed from all
partitions to which it was assigned, and all
authorization levels and other information about
that user will be deleted. Note that a user can
only be deleted from the partition in which it was
first assigned, and can only be deleted by a user
with a higher authority level. A User's security
code cannot be deleted by oneself.
OK TO DELETE
0 = NO , 1 = YES
USER CODE
DELETED
– 21 –
Accessing Other Partitions
To Access another Partition
Each keypad is assigned a default partition for display purposes, and will
show only that partition's information. But, if the user is authorized, a
keypad in one partition can be used to perform system functions in other
partitions by using the GOTO command. Note that only those partitions
authorized and programmed by the installer can be accessed in this manner.
To GOTO another partition:
READY
1. Enter your security code, then press
✳
+ partition number (0-8).
Entering partition number 0 will return the keypad to its original
partition.
The keypad will remain in the new partition
until directed to go to another partition, or
until 2 minutes has elapsed with no keypad
activity.
LOG-ON TO
PART. X COMPLETE
AAAA
2.
AAAA = alpha descriptor programmed by the
installer
X = partition number
Global Arming
The Global Arming option may be assigned for use by some users. If Global
Arming was enabled for use with your security code, a keypad prompt
(message) shown below appears after pressing one of the arming function
keys (STAY, INSTANT, AWAY, MAXIMUM, OFF).
The prompt displays all the partitions. The user
may only arm/disarm the partitions they are
assigned access to.
ARM P1 2 3 4 5 6 7 8
HIT 0-8 XXX- - X- -
To select the partition(s) that are to be armed,
enter the desired number 1-8. An "X" will appear
under that partition. Entering
a
partition's
number again will delete the “X” and that
partition will not arm when this prompt is exited.
Pressing 0 will turn all partitions the user is
assigned access to on/off.
When completed, press ✳ to exit. All the partitions
with the “X” will then arm/disarm.
– 22 –
Accessing Other Partitions (cont’d)
Global Arming Notes:
•
When performing a Global Arm, if there are faults in any of the selected
partitions, the system will enter a Summary Mode. Faulted zones in all
the selected partitions will be displayed. These faults must be corrected
or bypassed. This Summary Mode will end in approximately 120 seconds
if no keys are pressed.
•
When performing a Global Disarm, if any of the selected partitions has a
condition which would cause the keypad to beep (e.g., alarm memory or a
trouble condition), the system enters a Summary Mode and displays the
condition. This Summary Mode will end in approximately 120 seconds if
no keys are pressed.
Master Keypad Operation
A "Master" keypad is one that reflects the status of the entire system
(Partitions 1-8) on its display. This is useful because it eliminates the need
for a security officer in a building to have to "log-on" to various partitions
from one partition's keypad to find out where an alarm has occurred.
A description of a typical display follows:
SYSTEM 1 2 3 4 5 6 7 8
STATUS RRNN A T ∗ B
The status of each partition is directly below the partition number on the
display. Possible status indications include:
A = Armed Away
I = Armed Instant
B = Bypassed/Ready ∗ = Alarm
S = Armed Stay
R = Ready
M = Armed Maximum
N = Not Ready
T = Trouble
F = Fire Alarm
C = Comm Fail
P = AC Power Failure L = Low System Battery
To obtain more information regarding a particular partition, enter [∗] +
[Partition No.] (i.e., ∗4). This will allow viewing only of that partition. In
order to affect that partition, the user must log on with a code that has access
to that partition. Also, in order for a user of any partition to log onto the
"Master" partition (Partition 9) to view the status of all partitions, and to
perform any functions at the Master keypad, that user must have access to
all partitions. Otherwise, access will be denied.
– 23 –
Accessing Other Partitions (cont’d)
The following is an example of what would be displayed for a fault condition
on Zone 002 (Loading Dock Window) on Partition 1 (Warehouse) when
logging on from a keypad on Partition 9:
WHSE DISARMED
HIT ∗ FOR FAULTS
This is the normal display that appears at Partition 1's keypad(s). Pressing ∗
will display:
FAULT 002 LOADING
DOCK WINDOW
Additional zone faults will be displayed one at a time. To display a new
partition's status, press ∗ + [Partition No.]. This will display the status of the
new partition.
The "Armed" LED on a Master keypad will be lit only if all partitions have
been armed successfully. The "Ready" LED will be lit only if all partitions
are "ready to arm."
The sounder on a Master keypad will reflect the sound of the most critical
condition on all of the partitions. The priority of the sounds is as follows:
A. Pulsing fire alarm sounds
B. Steady burglar alarm sounds
C. Trouble sounds
The sounder may be silenced by pressing any key on the Master keypad.
– 24 –
Accessing Other Partitions (cont’d)
Common Lobby Operation
When an installation consists of a partition that is shared by users of other
partitions in a building, the shared partition may be assigned as a “common
lobby” partition for the system. An example of this might be in a medical
building where there are two doctors and a common entrance area.
This option employs logic for automatic arming and disarming of the common
lobby. Partitions may be set to affect and/or attempt to arm the common
lobby. This will affect the way the lobby will react when arming or disarming
activity occurs in another partition.
Partitions that affect the lobby will cause the following to occur:
a. When the first partition that affects the lobby is disarmed, the lobby will
also be disarmed.
b. The common lobby cannot be armed unless every partition selected to
affects the lobby is armed.
c. Arming the last partition that affects the lobby will not automatically
attempt to arm the lobby.
Partitions set to arm the lobby will cause the following to occur:
a. When the first partition that affects the lobby is disarmed, the lobby will
also be disarmed.
b. The common lobby cannot be armed unless every partition selected to
affects the lobby is armed.
c. Arming the last partition programmed to arm the lobby will
automatically attempt to arm the lobby. If any faults exist in the lobby
partition, or another partition that affects the lobby is disarmed, the
lobby cannot be armed, and the message “UNABLE TO ARM LOBBY
PARTITION” will be displayed.
The following chart summarizes how the common lobby partition will
operate:
Partition Affects
Lobby
Partition Arms
Lobby
Disarms When
Partition Disarms
Attempts to Arm
When Partition
Arms
Can Be Armed if
Other Partitions
Disarmed
NO
YES
YES
NO
NO
NO
NO
YES
YES
NO
NO
YES
NO
YES
YES
YES
NO
---ENTRY NOT ALLOWED---
– 25 –
Accessing Other Partitions (cont’d)
How User Codes Affect the Common Lobby
Codes with “Global” Arming
If your code is given “global arming” when it is defined, the system displays a
prompt that allows you to pick and choose the partitions to be armed or
disarmed. This eliminates the “automatic” operation of the lobby. Keep in
mind, however, that if attempting to arm all the partitions you have access
to, and another affecting partition is disarmed, (one you do not have access
to) you will not be able to arm the lobby, and the message “UNABLE TO
ARM LOBBY PARTITON” will be displayed.
Codes with “Non-Global” Arming
If arming with a non-global code, the lobby partition operation will be
automatic, as described in the previous table.
Other Methods of Arming/Disarming
When arming or disarming a partition that affects and/or arms the common
lobby in one of the following manners, lobby logic remains active:
•
•
•
•
Quick-Arm
Keyswitch
Wireless Button
Wireless Keypad
– 26 –
Checking For Open Zones
Using the ✳ READY Key
Before arming your system, all protected doors, windows and other protection
zones must be closed or bypassed (see BYPASSING section). Otherwise the
keypad will display a "Not Ready" message. Using the READY key will
display all zones that are faulted, making it easier for you to secure any open
zones.
To show faulted zones:
Note: Some keypads light a green LED when
the system is ready. If not lit, the system is not
ready to be armed.
DISARMED - PRESS
∗ TO SHOW FAULTS
READY
1. Do not enter security code, but simply press
✳
.
FAULT 005 FRONT
UPSTAIRS BEDROOM
Typical fault display
Secure or bypass the zones displayed before
arming the system. The "Ready" message will
2.
DISARMED
READY TO ARM
†
be displayed when all protection zones have
been either closed or bypassed.
†
NOTE: All or part of this message may be
replaced by a customized message programmed
by the installer. Bear this in mind whenever
the instructions indicate that the
"DISARMED" or "READY" message will be
displayed.
– 27 –
Displaying All Zone Descriptors
Using the ✳ READY Key
The Alpha Keypads can also display all the zone descriptors that are
programmed in your system. The abbreviated instructions for the READY
key will appear first, followed by the zone descriptors. Displaying all
descriptors is useful when you need to know the zone number of a particular
zone, as when bypassing zones.
The "Disarmed-Ready to arm" message must be displayed before zone
descriptors can be displayed.
READY
Press the
✳
key and hold down for at least 5 seconds.
– 28 –
Bypassing Protection Zones
Using the 6 BYPASS Key
This key is used when you want to arm your system with one or more zones
intentionally unprotected. Bypassed zones are unprotected and will not cause
an alarm when violated while your system is armed. All bypasses are
removed when an OFF sequence (security code plus OFF) is performed.
Bypasses are also removed if the arming procedure that follows the bypass
command is not successful.
Note: The system will not allow fire or emergency zones to be
bypassed.
To bypass zones, the system must be disarmed first.
BYPASS
1. Enter your security code and press
6
.
2. Enter zone number(s) for the zones to be bypassed (e.g., 001, 002, 003,
etc.).
Important! All single-digit numbers must be preceded by “00” (for
example, enter 001 for zone 1).
3. Press [∗] + [∗].
When finished, the keypad will display the
word BYPASS along with each bypassed zone
number. Wait for these zones to be displayed
before arming. Arming the system before
bypassed zones are displayed eliminates all
bypasses.
4.
BYPASS 007 FRONT
UPSTAIRS BEDROOM
Typical bypass message
Arm the system as usual when the keypad
displays "ready" to arm message.
5.
DISARMED BYPASS
READY TO ARM
– 29 –
Bypassing Protection Zones (cont’d)
Quick Bypass
Your system allows you to easily bypass all open (faulted) zones without
having to enter zone numbers individually.
NOTE: All bypasses are removed when an OFF sequence (security code plus
OFF) is performed.
To use the Quick Bypass feature:
BYPASS
1. Enter your security code and press
6
then press # .
In a few moments, all open zones will be
displayed along with the word BYPASS. Wait
for these zones to be displayed before arming.
Arming the system before bypassed zones are
displayed eliminates all bypasses.
BYPASS 007 FRONT
UPSTAIRS BEDROOM
Typical bypass message
2.
3.
Arm the system as usual when the keypad
displays the "ready" to arm message. Bypassed
zones are unprotected and will not cause an
alarm when violated while your system is
armed.
DISARMED BYPASS
READY TO ARM
Viewing Bypassed Zones
The system allows you to view bypassed zones that are presently bypassed
regardless of the status of the partition (armed, disarmed, etc.). To view
bypassed zones.
1. Enter your security code + # + 84.
2. All zones presently bypassed are automatically scrolled for display.
– 30 –
Bypassing Protection Zones (cont’d)
Group Bypass
Your system allows you to easily bypass a group of zones without having to
enter zone numbers individually. The system provides up to 15 groups. There
is no limit to the number of zones that may be assigned to any one group.
Check with your installer for a list of zones assigned to the group(s).
NOTES:
All bypasses are removed when an OFF sequence (security code plus OFF) is
performed.
Users must be assigned the following attributes to perform the group bypass
function:
•
•
•
Enabled for group bypassing
Access to the partition(s) containing the zones being bypassed
Global arming capability.
To use the Group Bypass feature:
BYPASS
1. Enter your security code and press
group number (01-15).
6
then press
✳
then enter the
In a few moments, all the zones in the group
will be displayed along with the word BYPASS.
Wait for these zones to be displayed before
arming. Arming the system before bypassed
zones are displayed eliminates all bypasses.
BYPASS 007 FRONT
UPSTAIRS BEDROOM
Typical bypass message
2.
Arm the system as usual when the keypad
displays the "ready" to arm message. Bypassed
zones are unprotected and will not cause an
alarm when violated while your system is
armed.
DISARMED BYPASS
READY TO ARM
3.
– 31 –
Bypassing Protection Zones (cont’d)
Zones Remaining Bypassed After Disarming
The system provides an option to allow all manually bypassed zones to remain
bypassed upon disarming (security code + OFF) of the partition. This option must be
programmed by your installer. Check with your installer to see if this option has been
enabled.
NOTES:
For each partition in which the option is enabled, the security code + OFF will no
longer unbypass zones. To unbypass ALL zones you must enter your security code + #
+ 64. To unbypass zones INDIVIDUALLY, you must enter your security code + 6 +
zone number.
Any zone that was automatically bypassed by the system will be unbypassed upon
disarming the system (e.g. STAY mode, Auto-STAY, etc.).
Vent zones and zones bypassed by a programmed Auto-Bypass schedule (Tme Driven
Event) are considered “manual bypasses” and will not be unbypassed upon disarming
the system.
Zones that were in a bypassed state at the time a System Shutdown is sent from the
Compass Downloading software will be unbypassed when the System Shutdown is
removed.
– 32 –
Arming Perimeter Only
(With Entry Delay ON)
Using the 3 STAY key
Use this key when you are staying home, but might expect someone to use
the entrance door later.
When armed in STAY mode, the system will sound an alarm if a protected
door or window is opened, but you may otherwise move freely throughout the
premises. Late arrivals can enter through the entrance door without causing
an alarm, but they must disarm the system within the entry delay period or
an alarm will occur.
The system provides three STAY modes. STAY mode 1, 2, and 3. STAY
modes 1 and 2, when activated automatically bypass specific zones assigned
by your installer to each of the STAY modes. If there are only Stay 1 zones,
entering Code+Stay[3] will automatically arm in Stay Mode 1; however if
there is at least one zone assigned to Stay Mode 2, you MUST enter either
Code+[3]+[1], Code+[3]+[2] or Code+[3]+[3], else the panel will not arm. If
Code+[3] is entered Stay Mode 1 prevails (even if there are Stay Mode 2
zones). Check with your installer for a list of the zones that are bypassed
during each STAY mode.
Close all perimeter windows and doors before arming (see
CHECKING FOR OPEN ZONES section)
STAY
1. Enter your security code and press
Enter your security code and press
Enter your security code and press
3
3
3
+
+
+
1 for STAY Mode 1.
2 for STAY Mode 2.
3 for STAY Mode 3.
The keypad beeps three times, displays the
armed message, and indicates which STAY
mode (1, 2 or 3).
ARMED ***STAY 1*
ZONE BYPASSED
2.
Note: "ZONE BYPASSED" in this display
simply indicates that some zones of protection
are not armed when using STAY mode.
– 33 –
Arming Perimeter Only
(With Entry Delay ON) (cont’d)
Auto-STAY Arming
Auto-stay allows the system to automatically bypass certain zones if upon
arming none of the entry/exit zones are faulted during the exit delay time (no
one exits the premises). The system provides an option to set each burglary
zone for Auto-stay. All zones enabled for auto-stay except for perimeter and
day/night types of zones, have exit delay time when the partition is armed.
Check with your installer for the zones assigned for Auto-STAY.
NOTES:
•
Auto-STAY applies to all four arming modes (AWAY, STAY, INSTANT
and MAXIMUM).
•
Arming the partition AWAY via an RF transmitter overrides the Auto-
stay feature (partition will not bypass zones programmed for auto-stay).
– 34 –
Arming Perimeter Only
(With Entry Delay OFF)
Using the 7 INSTANT Key
Important: If you are using a Graphic/Touch-Screen Keypad, NIGHT mode
is the same as INSTANT.
Use this key when you are staying home and do not expect anyone to use the
entrance door.
When armed in INSTANT mode, the system will sound an alarm if a
protected door or window is opened, but you may otherwise move freely
throughout the premises. The alarm will also sound immediately if anyone
opens the entrance door.
The system provides three INSTANT modes; INSTANT modes 1, 2 and 3.
INSTANT modes 1 and 2, when activated, automatically bypass specific
zones assigned by your installer to each of the INSTANT modes. INSTANT
mode 3, when activated, automatically bypasses all zones assigned to
INSTANT modes 1 AND 2. Check with your installer for a list of the zones
that are bypassed during each INSTANT mode.
Close all perimeter windows and doors before arming (see
CHECKING FOR OPEN ZONES section)
INSTANT
1. Enter your security code and press
Enter your security code and press
Enter your security code and press
7
7
7
+
+
+
1 for INSTANT Mode 1.
2 for INSTANT Mode 2.
3 for INSTANT Mode 3.
NOTE: If none of the zones in a partition are assigned to INSTANT mode 2,
then when the user enters [User Code] + [7] (INSTANT), all zones assigned
to INSTANT mode 1 are automatically bypassed.
The keypad beeps three times, displays the
armed message and indicates which INSTANT
mode (1, 2, or 3).
ARMED *INSTANT1
ZONE BYPASSED
2.
Note: "ZONE BYPASSED" in this display
simply indicates that some zones of protection
are not armed when using INSTANT mode.
– 35 –
Arming All Protection
(With Entry Delay ON)
Using the 2 AWAY Key
Use this key when no one will be staying on the premises.
When armed in AWAY mode, the system will sound an alarm if a protected
door or window is opened, or if any movement is detected inside the premises.
You may leave through the entrance door during the exit delay period
without causing an alarm. You may also reenter through the entrance door,
but must disarm the system within the entry delay period or an alarm will
occur.
Close all perimeter windows and doors before arming (see
CHECKING FOR OPEN ZONES section)
AWAY
1. Enter your security code and press
2
.
ARMED **AWAY**
YOU MAY EXIT NOW
The keypad will beep twice and will display the
armed message.
2.
Note: The "YOU MAY EXIT NOW" portion of
the message disappears when exit delay
expires.
– 36 –
Arming All Protection
(With Entry Delay OFF)
Using the 4 MAXIMUM Key
Use this key when the premises will be vacant for extended periods of time
such as vacations, etc., or when no one will be moving through protected
interior areas.
When armed in MAXIMUM mode, the system will sound an alarm if a
protected door or window is opened, or if any movement is detected inside the
premises. You may leave through the entrance door during the exit delay
period without causing an alarm, but an alarm will be sounded as soon as
someone reenters.
Close all perimeter windows and doors before arming (see
CHECKING FOR OPEN ZONES section).
MAXIMUM
1. Enter your security code and press
4
.
The keypad will beep twice and will display the
armed message.
ARMED *MAXIMUM*
YOU MAY EXIT NOW
2.
Note: The "YOU MAY EXIT NOW" portion of
the message disappears when exit delay
expires.
– 37 –
Quick Exit
Using the # + 9 Keys
The Quick Exit feature allows you to exit the armed partition without having
to disarm and then rearm the partition.
To Quick Exit the premises:
1. Press the # key and then press the 9 key.
2. The system will sound the exit beeps, if enabled, and will give you the
programmed exit delay time to leave the premises.
– 38 –
Disarming and Silencing Alarms
Using the 1 OFF Key
The OFF key is used to disarm the system and to silence alarm and trouble
sounds. See "SUMMARY OF AUDIBLE NOTIFICATION" section for
information which will help you to distinguish between FIRE and
BURGLARY alarm sounds.
IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the
premises, but call the police from a nearby safe location. If you return after an alarm has
occurred and the main sounder has shut itself off, the keypad will beep rapidly upon
entering, indicating that an alarm has occurred during your absence. LEAVE
IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
To disarm the system and silence burglary or fire alarms:
OFF
1. Enter your security code and press
1
.
DISARMED
READY TO ARM
2. The Ready message will be displayed (if no alarms have occurred while
armed) and the keypad beeps once to confirm that the system is disarmed.
IMPORTANT: It is not necessary to press the “OFF” key on the keypad to disarm
the system when it is in entry delay or alarm. Entering a valid user code alone causes
the system to disarm. All other times pressing the “OFF” key is needed. This is a SIA
CP-01 requirement.
If an invalid code is entered to silence an alarm condition, the keypad stops beeping
for 10-15 seconds. If a valid code is not entered during the 10-15 seconds, the keypad
resumes beeping.
Memory of Alarm
The keypad displays the zone number and type of alarm for any zone that
has an alarm condition. These messages will remain displayed until cleared
by a user. If an alarm has occurred, note the zone number displayed on the
keypad and repeat step 1 above to clear the "Memory of Alarm" and restore
the Ready message display. If the Ready message does not display, go to the
displayed zone and remedy the fault (close windows, etc.). If the fault cannot
be remedied, notify the alarm agency.
If the system was armed when the alarm occurred, repeat step 1 twice: once
to disarm the system, a second time to clear the display.
– 39 –
Using the Keyswitch
General
Your system may be equipped with a keyswitch for use when arming and
disarming a partition. A red and green light on the keyswitch plate indicate
the status of your system as follows:
Green Light: Lights when the system is disarmed and ready to be
armed (no open zones). If the system is disarmed and the
green light is off, it indicates the system is not ready (one or
more zones are open).
Red Light: Lights when system is armed or memory of alarm exists.
Lit Steady: Partition is armed in AWAY mode.
Slow Flashing: Partition is armed in STAY mode.
Rapid Flashing: Memory of alarm, indicating an alarm has occurred.
Arming
To arm in the AWAY mode, turn the key to the right for 1 second and
release. Keypads will beep twice and the
red light will stay on steady.
To arm in the STAY mode, turn the
key to the right and hold for longer than
10 seconds, then release. Keypads will
GREEN
RED
beep three times and the red light will
flash slowly.
Disarming
To disarm the partition, turn the key
to the right and release. If an alarm has
occurred, the red light will be flashing
rapidly (memory of alarm).
keyswitch-001-V1
– 40 –
Chime Mode
Using the 9 Key
Your system can be set to alert you to the opening of a door or window while
it is disarmed by using CHIME mode. When activated, three tones will sound
at the Keypad whenever a protected perimeter door or window is opened, and
the Not Ready message will be displayed. Pressing the READY key will
display the open protection points.
Note that Chime mode can be activated only when the system is disarmed.
1. To turn Chime Mode on, enter the security code and press 9 .
The CHIME MODE ON message will appear
for about 2 seconds then disappear. To display
this message again (to determine whether
chime mode is on or off), simply press and hold
down the CHIME key for 5 seconds.
CHIME MODE ON
2. To turn Chime Mode off, enter the security code and press 9 again.
The CHIME MODE OFF message will appear
for about 2 seconds then disappears. To display
this message again (to determine whether
chime mode is on or off), simply press and hold
down the CHIME key for 5 seconds.
CHIME MODE OFF
– 41 –
Viewing Alarm Company Messages
General Information
Users of the system may periodically receive messages on their display
screens from their monitoring agency or installer. When a message is waiting
to be viewed, the message shown below will appear.
MESSAGE. PRESS 0
FOR 5 SECS.
1. Press and hold down 0 key for 5 seconds.
2. The message could take up to four screens to display all the information
available.
NOTE: Any message sent by the central station downloader may be viewed
at any partition’s keypad.
– 42 –
Panic Keys
(For Manually Activating Silent and/Or Audible Alarms)
Using Panic Keys
Your system may have been programmed to use special key combinations to
manually activate panic functions. The functions that might be programmed
are Silent Emergency, Audible Emergency, Personal Emergency, and Fire.
See your installer for the function(s) that may have been programmed for
your system.
Active Panic Functions
(Your installer should note which
function(s) is active in your
system.)
To use a paired key panic function,
simply press both keys of the assigned
pair at the same time.
Keys
1 and *
3 and #
* and #
A
Zone Function
995
996
999
995
999
996
If your keypad(s) have lettered keys for
panic functions, press the designated
key and hold down for at least 2 seconds
to activate the panic function.
B
SIA Installations: Lettered keys not for use
in CP-01 installations.
C
A silent emergency sends a silent alarm signal to the central station, but
there will be no audible alarms or visual displays.
An audible emergency sends an emergency message to the central station
(if connected) and will sound a loud, steady alarm at your keypad and at any
external sounders that may be connected (ALARM plus a zone number
would also be displayed).
A personal emergency alarm sends an emergency message to the central
station (if connected) and will sound at Keypads, but not at external bells or
sirens. (ALARM plus a zone number would also be displayed.)
A fire alarm sends a fire alarm message to the central station and will
uniquely sound external bells and sirens (FIRE plus a zone number would
also be displayed).
– 43 –
Speed Key (Macros)
General Information
The “A”, “B”, “C”, and/or “D” keys can be used to activate a string of
commands up to 32 keystrokes each. These commands are known as a macro
and are stored in the system’s memory. Typical Speed Key functions include:
•
Arming sequences that involve first bypassing certain zones before
arming.
•
•
Seldom used but repeatable sequences.
Relay activation sequences.
NOTE: If a speedkey function includes an arming sequence and the user
executing it has global arming, all partitions the user can global arm will
arm.
Defining
To program a macro, enter your user code +
appears:
#
+ [D]. The following
ENTER SPEED KEY #
01-32
00=QUIT
Enter the 2-digit Speed Key number (01-32) being defined and press [*].
Enter up to 32 keystrokes. A Speed Key sequence can include different
commands. Press the "D" key to separate different commands. For example,
you may want to perform the following sequence.
GOTO partition 2......................Enter *2
Bypass zones 10 & 11...............Press bypass [6], then the zone numbers 010
& 011
Arm in maximum mode............Press maximum [4] key
Return to partition 1 ................Enter *1
To program that Speed Key sequence, type the following:
*2 D 6010011 D 4 D *1 D D
Note that the "D" key is pressed after each command. Press "D" twice to
complete the entry and exit.
NOTE: When defining Speed Key sequences, do not use the
#
key to
represent Quick Arming. The system uses the code entered in response to
the prompt to initiate commands in a Speed Key sequence, so the quick arm
– 44 –
Speed Key (Macros) (cont’d)
key is unnecessary. The system interprets the use of the
Key sequence as its designated function only.
#
key in a Speed
Executing
To execute a Speed Key sequence, do the following:
If a lettered key, A-B-C has been assigned as a Speed Key, press and hold
down the appropriate key (about 2 seconds). If a user code is required for any
part of the Speed Key sequence, the following prompt appears. Otherwise,
the Speed Key sequence automatically begins.
ENTER USER CODE
✴✴✴✴
Enter your user code.
automatically.
The defined Speed Key sequence will begin
To activate a Speed Key not assigned to the A-B-C keys, press and hold down
the [D] key for 2 seconds until the following prompt appears:
ENTER SPEED KEY #
01-32
00=QUIT
Enter the desired Speed Key number.
If a user code is required for any part of the Speed Key sequence, the
following prompt appears. Otherwise, the Speed Key sequence automatically
begins.
ENTER USER CODE
✴✴✴✴
Enter your user code. The programmed Speed Key sequence will begin
automatically.
– 45 –
Access Door Control
General Information
Your system may be set up such that a locked access door (such as in a lobby)
can be unlocked momentarily or for a specific period of time, using a keypad
command. Ask your installer if this has been done in our system.
Executing
There are several entries that can be entered at the keypad to activate this
command:
1. Enter your security code + [0]. The door will unlock for 2 seconds.
2. Enter your security code +
#
+ 73, or security code + # + 74 + access
point. The door will unlock for a specific period of time.
3. Enter your security code + + 75 + access point + function. The
#
functions available are None, Grant, Protect and Bypass. Grant will
temporarily unlock a door to allow an access. Protect will cause a door to
unlock only when a valid access is received. Bypass will cause a door to
be permanently unlocked to allow continuous access.
4. Access control functions may also be executed use your security code +
+ 77. See Using #77 Instant Activation Mode later in this manual.
– 46 –
Using #70 Relay Menu Mode
General Information
Your system may be set up so that certain lights or other devices can be turned
on or off by using the #70 command from either a keypad or a telephone keypad
(if 4286 VIP module is used). Ask your installer if this has been done in your
system.
To activate relays from a keypad, enter 4-digit security code +
#
+70.
Follow the keypad prompts described below.
To activate relays using a telephone and 4286 VIP module, first dial the 2-
digit phone access code. When the system acknowledges the access, enter 4-digit
security code +
#
+ 70. The following prompts/voice responses will begin.
ENTER DEVICE NO.
Voice: "ENTER DEVICE CODE NOW"
00=QUIT
01
Enter the 2-digit number of the device to be
activated.
Note that if an invalid number is entered, the
system will simply ask you to reenter the number.
NN DEVICE IS OFF
HIT 0=OFF , 1=ON
Voice: "voice descriptor DEVICE nn ON/OFF. FOR
voice descriptor ON ENTER 1, FOR voice descriptor
OFF ENTER 0"
Press 0 or 1 to turn the device off or on respectively.
"nn" represents the 2-digit device number and voice
descriptor is the relay voice descriptor programmed
by the installer.
NN DEVICE IS OFF
HIT THE "✴" KEY
Voice: "voice descriptor DEVICE nn ON/OFF. TO
EXIT ENTER 00 NOW"
From a keypad, press ✴ to continue. The ENTER
DEVICE NO. prompt will appear.
From a telephone keypad, enter 00 to exit, or
enter the next relay number to be programmed. The
current on/off state of that relay will be
annunciated as described above. Alternatively, if 6
seconds elapses with no key depression, the 4286
VIP module will annunciate the "ENTER DEVICE
CODE NOW" message.
– 47 –
Using Schedules
Delaying the Closing Time
Your system's programmed schedules may automatically arm the system at a
predetermined time. In the event a user must stay on the premises later than
usual, users with master or manager authority levels can manually delay the
automatic arming (closing) time up to 2 hours. To delay the closing time:
1. Enter your security code (master or manager authority levels only).
2. Press the # key, followed by 82.
3. A menu prompt will be displayed, asking for the number of hours of delay.
Enter the desired number of hours of delay, 1 or 2.
The system automatically exits this mode after
entry.
CLOSING DELAY?
KEY 0-2 HOURS
Note that the delay is from the scheduled closing time, not from the
time the command is entered.
IMPORTANT: The selected delay cannot be reduced once it is set. A 1
hour delay can be increased to 2 hours, though.
4. The system will automatically send a message to the central station
informing them that the programmed schedule has been changed.
Temporary Open/Close Schedules
Temporary schedules allow you to override the normal schedules
programmed by the installer. Temporary schedules can be in effect for up to
one week, and take effect as soon as they are programmed.
They are comprised of an arming (closing) time window and a disarming
(opening) time window. A time window is simply a defined period of time, at
the end of which arming or disarming will occur.
Before programming, use a worksheet similar to the one below to plan your
schedule. This will make it easier when actually programming the schedule.
Arm/Disarm
Mon
Tue
Wed
Thu
Fri
Sat
Sun
Windows
Disarm Window
Start Time HH:MM
Stop Time HH:MM
Arm Window
Start Time HH:MM
Stop Time HH:MM
– 48 –
Using Schedules (cont’d)
Programming Temporary Schedules
Temporary schedules only affect the partition from which it is entered.
Temporary schedules can be reused at later dates simply by scrolling (by
pressing #) to the DAYS? prompt (described below) and activating the
appropriate days. This should be considered when defining daily time
windows. Note that only users with authority level of manager or higher can
program temporary schedules.
To program temporary schedules:
1. Enter your security code.
2. Press the # key followed by 81.
3. The following prompts will appear.
The cursor will be positioned on the tens of hours
digit of the start time for Monday's disarm
window. Enter the desired hour. Press * to move
to the minutes field. The minutes are entered in
the same manner. The AM/PM indication is
changed by hitting any key, 0-9, while the cursor
is under the letter A/P position. Repeat for the
stop time entry. Press the * key to move to the
arming window for Monday.
MON DISARM WIND.
07:45AM 08:45AM
Press # to move to the next screen display
without making changes.
The cursor will be positioned on the tens of hours
digit of the start time for the arm window. Repeat
the previous steps to enter the start and stop
time for Monday's arming window.
MON ARM WINDOW
07:45AM 08:45AM
After the windows for that day have been
completed, the system will prompt for disarm and
arm time windows for the next day. Repeat the
procedure for all days of the week.
TUE DISARM WIND.
07:45AM 08:45AM
When all of the days have been completed, the
system will ask which days are to be activated.
– 49 –
Using Schedules (cont’d)
This is the prompt that actually activates the
DAYS ? MTWTFSS
HIT 0-7 X X
temporary schedule, and allows the temporary
schedule to be customized to a particular week's
needs. To select the days which are to be
activated, enter the desired number 1-7 (Monday
= 1). An "X" will appear under that day,
indicating the previously entered schedule for
that day is active. Entering a day's number again
will deactivate that day. Pressing 0 will turn all
days on/off.
The temporary schedule will only be in effect for
the days which have the letter x underneath
them. As the week progresses, the days are reset
to the inactive state.
When completed, press * to exit the temporary
schedule entry mode.
– 50 –
Programming Device Timers
General Information
Device timers consist of an ON time & an OFF time, and selected days of the
week in which they are active. There are up to 20 timers that can be used to
control various devices, such as lights or appliances. Your installer will have
programmed the appropriate devices into the system (up to 96 devices can be
programmed).
Each timer controls a single device (designated as an output number) that
you select. For example, timer 1 might be set to turn the porch lights on at
7:00pm and turn them off at 11:00pm. Timer 2 might turn on the air
conditioner Monday-Friday at 4:30pm to cool the premises before you arrive
at 5:00pm, and turn it off at 10:00pm when you are retiring for the night. If
desired, different timers can control the same device. For example, timer 2
could be used Monday-Friday as in the previous example, and timer 3 could
be set to turn the air conditioner on and off at different times Saturday and
Sunday.
To enter the device timer menu mode:
Enter your security code, then press the # key followed by 83.
Up to 20 timers can be programmed. Each timer
is identified by a number 1-20. Enter the desired
timer number to be programmed (1-20). Press *
to accept entry.
OUTPUT TIMER # ?
01-20,00=QUIT 01
If that timer number has already been
programmed, a summary screen will appear. In
this example:
06 07:00P 11:45P
PORCH LITE 04
06 = Timer #
04 = Output Device # affected by this timer
PORCH LITE = Output Descriptor for Device 4
07:00PM = Start Time;
11:45PM = Stop Time
Press * to continue.
See your installer for
device numbers.
Enter the desired output device number (1-96).
As the number is entered, the device's description
will appear.
00 ENTER OUTPUT#
00
To delete a previously programmed timer, enter
00 as the output number.
– 51 –
Programming Device Timers (cont’d)
Enter the time you want the device turned on
00 ON TIME ?
00:00 PM
using 00:01 - 11:59 format. When the display
shows the desired time, press the * key to move
to the AM/PM field. Press any key 0-9 to change
the AM/PM indication.
Enter 00:00 if this timer is not being used to turn
something ON for the days selected below. (Ex.
using one timer to turn lights on one day and
using another timer to turn them off on another
day).
Enter the time you want the device turned off
using 00:01 - 11:59 format. When the display
shows the desired time, press the * key to move
to the AM/PM field. Press any key 0-9 to change
the AM/PM indication.
00 OFF TIME ?
00:00 PM
Enter 00:00 if this timer is not being used to turn
something OFF for the days selected below. (Ex.
using one timer to turn lights on one day and
using another timer to turn them off on another
day).
Select the days on which the device is to be
activated by entering 1-7 (Monday = 1). An "X"
will appear under that day, indicating the output
for that day is active. Entering a day's number
again will deactivate that day. Pressing 0 will
turn all days on/off. The outputs will only be in
effect for the days that have the letter x
underneath them. As the week progresses, the
days are reset to the inactive state, unless the
permanent option is selected (next screen
prompt). When completed, press * to continue.
00 DAYS? MTWTFSS
HIT 0-7
X X
Answering 1 (YES) means the system executes
this timer continuously. Answering 0 (NO)means
the system executes each day's output only once.
00 PERMANENT ?
0 = NO, 1 = YES
0
– 52 –
Programming Device Timers (cont’d)
Randomize Output Device Times
Devices in your system may be set for a random schedule, whereby they will
turn on and off at different times each day. This is useful when going on
vacation and you desire the turning on and off of the lights to the give the
appearance of someone being home. Your installer sets these devices for a
random schedule. You can initiate a random schedule by either of the
following methods:
1. Enter your security code and press # followed by 41.
This will randomize, up to 30 minutes, the activation time of all devices,
programmed for randomization, assigned to the partition the sequence is
entered in. Enter the sequence again to turn off the random schedule.
2. Enter your security code and press # followed by 42.
This is the same as the method above, except the randomization occurs
only on devices with activation times within 6 PM and 5 AM. Enter the
same sequence again to turn off the random schedule.
– 53 –
Using #77 Instant Activation Mode
The #77 Instant Activation Mode is used to activate outputs, bypass zones,
etc. immediately upon exiting the #77 Mode. The actions that may be
activated are relay commands, arm/disarm commands, zone bypassing
commands, and open/close access conditions.
Relay Commands
Action Code
Action Specifier
01
02
03
04
05
06
07
08
09
10
Relay On
Relay Off
Relay Close for 2 seconds
Relay Close XX minutes ✳
Relay Close YY seconds ✳
Relay Group On
Relay #
Relay #
Relay #
Relay #
Relay #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Relay Group #
Relay Group Off
Relay Group Close for 2 seconds
Relay Group Close XX minutes ✳
Relay Group Close YY seconds ✳
✳ Check with your installer for the amount of time.
Arm/Disarm Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices
for automatic arming and disarming functions.
"During" can be used to arm or disarm the control for a specific time only.
For example, if "during" is selected with Arm-STAY, the system will
automatically Arm-STAY at the beginning of the window and automatically
disarm at the end of the window.
Action Code
Action Specifier
20
21
22
23
24
25
26
Arm-STAY
Arm AWAY
Disarm
Force Arm STAY (Auto-bypass faulted zns)
Force Arm AWAY (Auto-bypass faulted zns)
Arm INSTANT
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Partition(s)
Arm MAXIMUM
– 54 –
Using #77 Instant Activation Mode (cont’d)
Bypass Commands
Activation times 1 (Beginning), 2 (End), 3 (During) are the only valid choices
for bypass commands. If 3 (During) is selected for auto-bypassing, the
system bypasses the zone(s) specified on a particular zone list at the
beginning of the window and unbypasses them at the end of the window. If it
is selected for auto unbypassing, the system removes the bypass at the
beginning of the window and restores the bypass at the end of the window.
Action Code
Action Specifier
30
31
Auto bypass - Zone list
Auto unbypass - Zone list
Zone list #
Zone list #
Open/Close Windows
Activation time 3 (During) is the only valid choice for these commands.
Action Code
Action Specifier
40
41
42
Enable Opening Window by partition
Enable Closing Window by partition
Enable Access Window for access group
Partition(s)
Partition(s)
Access Group
Access Control Commands
Action Code
Action Specifier
55
56
57
58
59
60
61
62
63
64
66
67
68
69
70
71
72
73
74
Access Point Grant
Access Point Grant with Override
Access Point Protect
Access Point Bypass
Access Point Lock
Access Point Exit
Access Point Group Grant
Access Point Group Grant with Override
Access Point Group Protect
Access Point Group Bypass
Access Point Group Exit
Access Point Partition Grant
Access Point Partition Grant with Override
Access Point Protect by Partition
Access Point Bypass by Partition
Access Point Lock by Partition
Access Point Exit by Partition
Access Point Trigger On
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Access Point #
Group #
Group #
Group #
Group #
Group #
Partition #
Partition #
Partition #
Partition #
Partition #
Partition #
Trigger #
Access Point Trigger Off
Trigger #
– 55 –
Using #77 Instant Activation Mode (cont’d)
Additional Commands
Action Code
Action Specifier
77
78
Access Point Group Enable
Access Point Group Disable
Group #
Group #
To enter the Instant Activation Mode:
Enter your security code, then press the # key followed by 77.
Enter the code for the desired action. The
action codes are the events that are to take place
when either the system exits the #77 Mode or the
scheduled time is reached, depending on the action
selected.
ACTION ?
Press [✳] to continue.
Enter the action specifier. This defines what the
action will affect (relay, relay group, partition, zone
list, user group). The action specifier screen prompt
varies, depending on the type of action selected.
As an example, if you selected “Auto Bypass” as the
action, the action specifier prompt would be:
ZONE LIST ?
Enter 1 (YES) or 0 (NO).
Press [✳] to continue.
ARE YOU SURE ?
1 = YES 0 = NO
0
Enter 1 (YES) or 0 (NO).
Press [✳] to continue.
QUIT MENU MODE?
1 = YES 0 = NO
– 56 –
Event Log Procedures
General Information
The system has the ability to record various events in a history log wherein each event is
recorded in one of five categories (listed below), with the time and date of its occurrence. The
Event Log holds up to 1000 events, with the oldest event being replaced by the logging of any
new event after the log is full. Using an alpha keypad, the Event Log can be viewed one
category at a time, or can display all events, regardless of category (ALL EVENT LOG). The
system also allows selection of displaying the COMPLETE log, or only those events occurring
since the last installer service (RECENT). In addition, events in the other partitions can be
viewed by users authorized to access those partitions. Note that events are displayed in
chronological order, from most recent to oldest.
To Display the Event Log
1. Enter CODE + # + [6] + [0]
2. Select the display mode.
RECENT: Displays only those events occurring since last Event Log Clear command was
executed.
COMPLETE: Displays complete event log (up to 1000 events).
Press the desired key, 0 or 1.
ENTER 0 = RECENT
1 = COMPLETE
3. Select the partition, 0-8.
Enter the partition number for the partition whose events are to be displayed.
Entering 0 (NO) will display all partitions' events.
SCAN LOG BY PART
0 = NO 1-8 = PART#
4. Use the [3] & [1] keys (for next and previous categories respectively) to display the
categories of events.
Press [8] to select a category and display the first event. Press [8] again for each
subsequent event.
Shows burglary alarm occurred in zone 3 (C003) of partition 1 (P1), at 12:02AM on
January 1.
P1 01/01 12:02AM
BURGLARY C003
Typical
Event Log
Display
– 57 –
Event Log Procedures (continued)
After the last event has been displayed, the END OF EVENT LOG message appears for
a few seconds, then the system automatically displays the RECENT/COMPLETE mode
select screen again (see step 2).
5. To EXIT the Event Log:
Press [∗] at any time.
ALARM EVENT LOG Typical
TYPE
CCC UUU Category
Select Screen
ALARM EVENT LOG
Displays time and date for zones that has either caused an alarm or has been restored in the
selected partition.
CHECK EVENT LOG
Displays time and date for zones that has caused a trouble or supervisory condition in the
selected partition.
BYPASS EVENT LOG
Displays time and date for zones that has been bypassed in the partition.
OPEN EVENT LOG
Displays time, date and user number or 6-character descriptor for the user, if programmed,
for each arming and disarming of the system for the partition selected.
SYSTEM EVENT LOG
Displays time and date for system problems, such as AC Loss, low battery, etc., regardless of
partition.
ALL EVENT LOG
Displays all categories of events in chronological order.
See your Installer for additional information concerning the event log.
– 58 –
Setting the Time and Date
1. Enter Installer or Master Code + # + 63. Typical display shows:
TIME/DATE – THU
12:01 AM 01/01/10
The day of the week is automatically calculated based on the date entered. Time and date
entries are made by simply entering the appropriate hour, minute, month, day and year.
Press [∗] to move the cursor to the right of the display, to the next position.
Press [#] to move the cursor to the left of the display, to the previous position.
2. Enter the hour. Then press [∗] to move to the “minutes” field.
3. Enter the minutes. Press [∗] to move to the AM/PM position.
4. Press any key 0-9 to change AM to PM, or PM to AM. Press [∗] to move cursor to the
“month” field position.
5. Enter the month using a 2-digit entry. Press [∗] to move cursor to the “day” field position.
6. Enter the day using a 2-digit entry. Press [∗] to move cursor to the “year” field position.
7. Press [∗] to exit the real-time clock edit mode.
– 59 –
Testing the System (To Be Conducted Weekly)
Using the 5 TEST Key
The TEST key puts your system into Test mode, which allows each protection point to be
checked for proper operation.
1. Disarm the system and close all protected windows, doors, etc. READY should be
displayed.
TEST
2. Enter your security code and press the
5
key.
3. The external sounder should sound for 3 seconds and then turn off. If the sounder
does not sound, it may be due to dialer communication activity. Wait a few minutes
and try again. If the sounder still does not sound, CALL FOR SERVICE
IMMEDIATELY.
4. The keypad will sound a single beep every 15 seconds as a reminder that the system
is in Test mode. Each time a protection zone is faulted (opened), the keypad should
beep three times. If the sounder does not sound, CALL FOR SERVICE
IMMEDIATELY.
NOTES:
•
No alarm reports will be sent to the central monitoring station while the system is in
Test mode.
•
The system will automatically exit the Test mode if there is no activity (no doors or
windows are opened and closed, no motion detectors are activated, etc.) for 1 hour. The
system will beep the keypad(s) twice every 15 seconds during the last 5 minutes as a
warning that it is about to exit the Test mode and return to normal operation.
Testing Your System
1. Open and close each protected door and window in turn and listen for three beeps.
Each faulted protection point should appear on the display.
2. Walk in front of any motion detectors (if used) and listen for three beeps as
movement is detected (wireless motion detectors have a 3-1/2 minute lockout
between trips). Each detector’s should appear on the display when it is activated.
3. Follow the manufacturer's instructions to test all smoke detectors to ensure that all
are functioning properly. Each detector should appear on the display when activated.
4. When all protection points have been checked, there should be no zone identification
numbers displayed. If a problem is experienced with any protection point (no
confirming sounds, no display), CALL FOR SERVICE IMMEDIATELY.
5. Turn off Test mode by entering the security code + the OFF key.
– 60 –
Fire Alarm System
Your fire alarm system (if installed) is on 24 hours a day, providing continuous
protection. In the event of an emergency, the smoke and heat detectors automatically
send signals to your Control, triggering a loud interrupting sound from the keypad
and the optional exterior sounders. FIRE appears at your keypad and remains on
until you silence the alarm.
NOTES:
• All smoke detectors must be tested monthly by pressing the TEST button located on
the detector. Be aware that your keypad(s) and local siren(s) will activate (enter
your 4-digit code + [Off] to silence). If your system is monitored by a central station
you must first call the central station to advise them that a test is in progress. If the
TEST button does not cause the detector to activate it must be replaced
immediately.
• Ask your installer if your system is programmed for fire alarm verification, which
can help reduce false alarms from smoke detectors.
In Case Of Fire Alarm
1. Should you become aware of a fire emergency before your detectors sense the
problem, go to your nearest keypad and manually initiate an alarm by pressing
the panic key assigned as FIRE emergency (if programmed by the installer) and
hold down for at least 2 seconds.
2. Evacuate all occupants from the premises.
3. If flames and/or smoke are present, leave the premises and notify your local Fire
Department immediately.
4. If no flames or smoke are apparent, investigate the cause of the alarm. The
descriptor of the zone(s) in alarm appears at the keypad.
Silencing a Fire Alarm
1. Silence the alarm by entering your code and pressing the OFF key. To clear the
display, enter your code and press the OFF key again
2. If the keypad does not indicate a READY condition after the second OFF
sequence, press the READY key to display the faulted zone(s). Be sure to check
that smoke detectors are not responding to smoke or heat producing objects in
their vicinity. Should this be the case, eliminate the source of heat or smoke.
3. If this does not remedy the problem, there may still be smoke in the detector.
Clear it by fanning the detector for about 30 seconds.
4. You can clear the display by entering your code + the OFF key.
– 61 –
Trouble Conditions
Typical Trouble Displays
The word CHECK or TRBL on the Keypad's display, accompanied by a rapid
"beeping" at the Keypad, indicates that there is a trouble condition in the
system.
To silence the beeping sound for trouble conditions, press any key.
•
A display of “CHECK” or “TRBL” accompanied by a display of "CALL
SERVICE" indicates that a problem exists with the system that
eliminates some of the protection.
IMMEDIATELY.
CALL FOR SERVICE
•
A display of “CHECK” or “TRBL" accompanied by a display of one or
more zone descriptors indicates that a problem exists with those zone(s)*.
First, determine if the zone(s) displayed are intact and make them so if
they are not. If the problem has been corrected, the display of the zone
descriptor(s) and “CHECK” or “TRBL” should disappear. If not, key an
OFF sequence (Code plus OFF) to clear the display. If the display
persists, CALL FOR SERVICE IMMEDIATELY.
•
•
A display of “CHECK” or “TRBL” accompanied by a numeric display of
“6XX,” where XX = 01-32, indicates a trouble on a supervised relay
(corresponding relay number 01-32).
A display of “CHECK” or “TRBL” accompanied by a numeric display of
“8XX,” where XX = 00-30, indicates a trouble on a peripheral device
(connected to the panel’s keypad terminals) of a corresponding device
address (00-30).
•
A display of “CHECK” or “TRBL” accompanied by a numeric display of
“9XX,” where XX = 00-99, indicates a system trouble exists (RF
Receivers, Bell output, etc.). These zones are as follows:
970: Bell Supervision
988: 2nd RF Receiver – not receiving signals
990: 1st RF Receiver – not receiving signals
997: Polling Loop Short
•
A display of "COMM. FAILURE" at the Keypad indicates that a failure
has occurred in the telephone communication portion of your system.
CALL FOR SERVICE IMMEDIATELY.
– 62 –
Trouble Conditions (cont’d)
•
•
•
A display of "Phone Line Cut" accompanied by rapid beeping at the
Keypad indicates that a failure has occurred in the telephone line. CALL
FOR SERVICE IMMEDIATELY.
A display of "SYSTEM LO BAT", accompanied by a once per minute
"beeping" at the Keypad indicates that a low system battery condition
exists. CALL FOR SERVICE IMMEDIATELY.
A display of "LO BAT" and a zone descriptor, accompanied by a once per
minute "beeping" at the Keypad indicates that a low battery condition
exists in the wireless transmitter displayed. CALL FOR SERVICE
IMMEDIATELY.
•
A display of "MODEM COMM" indicates that the control is on-line with
the central station's remote computer. The control will not operate while
on-line.
Power Failure
If the POWER indicator is off, operating power for the system has stopped
and is inoperative. CALL FOR SERVICE IMMEDIATELY. If the POWER
indicator is on, but the message "AC LOSS" is displayed, the Keypad is
operating on battery power only. If only some lights are out on the premises,
check circuit breakers and fuses and reset or replace as necessary. CALL
FOR SERVICE IMMEDIATELY if AC power cannot be restored.
SERVICING INFORMATION
Your local Honeywell dealer is the person best qualified to service your alarm
system. Arranging some kind of regular service program with him is
advisable.
Your local Honeywell dealer is:
Name:
Address:
Phone:
– 63 –
Recommendations for Proper Protection
The following recommendations for the location of fire and burglary detection
devices help provide proper coverage for the protected premises.
Recommendations for Smoke and Heat Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to the
recommendations contained in the National Fire Protection Association's (NFPA) Standard
#72 noted below.
Early warning fire detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: For minimum protection
a smoke detector should be installed outside of each separate sleeping area, and on each
additional floor of a multi-floor family living unit, including basements. The installation
of smoke detectors in kitchens, attics (finished or unfinished), or in garages is not
normally recommended.
For additional protection the NFPA recommends that you install heat or smoke detectors in
the living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility and
storage rooms, basements and attached garages.
KITCHEN
KITCHEN
BDRM
DINING
BEDROOM
BEDROOM
TV ROOM
DINING
LIVING ROOM
BDRM
BEDROOM
BEDROOM
LIVING ROOM
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
BEDROOM
TO
BR
BEDROOM
BEDROOM
KTCHN
GARAGE
CLOSED
DOOR
LVNG RM
.
BASEMENT
floor_plan-001-V1
– 64 –
Recommendations for Proper Protection (cont’d)
In addition, we recommend the following:
Install a smoke detector inside every bedroom where a smoker sleeps.
Install a smoke detector inside bedrooms where electrical appliances (such as portable
heaters, air conditioners or humidifiers) are used.
Install a smoke detector inside every bedroom where someone sleeps with the door partly
or completely closed. Smoke could be blocked by the closed door. Also, an alarm in the
hallway outside may not wake up the sleeper if the door is closed.
Install a smoke detector at both ends of a hallway if the hallway is more than 40 feet (12
meters) long.
Install smoke detectors in any room where an alarm control is located, or in any room
where alarm control connections to an AC source or phone lines are made. If detectors are
not so located, a fire within the room could prevent the control from reporting a fire or an
intrusion.
Recommendations for Proper Intrusion Protection
For proper intrusion coverage, sensors should be located at every possible point of entry to a
home or commercial premises. This would include any skylights that may be present, and
the upper windows in a multi-level building.
In addition, we recommend that radio backup be used in a security system so that alarm
signals can still be sent to the alarm monitoring station in the event that the telephone lines
are out of order (alarm signals are normally sent over the phone lines, if connected to an
alarm monitoring station).
– 65 –
Emergency Evacuation
Establish and regularly practice a plan of escape in the event of fire. The following steps are
recommended by the National Fire Protection Association:
1. Position your detector or your interior and/or exterior sounders so that
they can be heard by all occupants.
2. Determine two means of escape from each room. One path of escape
should lead to the door that permits normal exit from the building. The
other may be a window, should your path be impassable. Station an
escape ladder at such windows if there is a long drop to the ground.
3. Sketch a floor plan of the building. Show windows, doors, stairs and
rooftops that can be used to escape. Indicate escape routes for each room.
Keep these routes free from obstruction and post copies of the escape
routes in every room.
4. Assure that all bedroom doors are shut while you are asleep. This will
prevent deadly smoke from entering while you escape.
5. Try the door. If the door is hot, check your alternate escape route. If the
door is cool, open it cautiously. Be prepared to slam the door if smoke or
heat rushes in.
6. Where smoke is present, crawl on the ground; do not walk upright.
Smoke rises and may overcome you. Clearer air is near the floor.
7. Escape quickly; don't panic.
8. Establish a common meeting place outdoors, away from your house,
where everyone can meet and then take steps to contact the authorities
and account for those missing. Choose someone to assure that nobody
returns to the house — many die going back.
– 66 –
Maintaining Your System
Taking Care of Your System
The components of your security system are designed to be as free of
maintenance as possible. However, there are some things you can do to make
sure that your system is in reliable working condition.
1. Test your system weekly.
2. Test the system after any alarm occurs (see TESTING THE SYSTEM).
Replacing Batteries in Wireless Sensors
Wireless sensors
may not have
been used in your
security system
Each wireless sensor in your system has a 9-volt or 3-volt battery. The system
detects a low battery in any wireless sensor, including smoke detectors, the
optional personal emergency transmitter, and the optional portable wireless
keypad. (A low battery in a portable wireless keypad is detected as soon as
one of its keys is pressed, and the keypad will display 00.)
Alkaline batteries provide a minimum of 1 year of operation, and in most
units and applications, provide 2–4 years of service. Actual battery life will
depend on the environment in which the sensor is used, the number of signals
that the transmitter in the sensor has had to send, and the specific type of
sensor. Factors such as humidity, high or low temperatures or large swings
in temperature, may all lead to the reduction of actual battery life in an
installation.
If you have a low battery in a wireless sensor, a low battery message
is displayed on the keypad.
In addition, a battery-operated smoke detector with a low battery also emits
a single "chirp" sound once approximately every 20-30 seconds, identifying
itself as the smoke detector with the weak battery. If you do not replace a
smoke detector's low battery, the smoke detector may sound continuously, as
if there were a fire alarm.
NOTE: The low battery message comes on as a warning that battery
replacement in indicated sensor(s) is due within 30 days. In the meantime,
the sensor(s) causing the low battery indication is still fully operational.
IMPORTANT: Use only batteries recommended by your installer as
replacement.
– 67 –
Maintaining Your System (cont’d)
Silencing Low Battery Warning Tones at the Keypad
The keypad’s warning tones can be silenced by performing an OFF sequence
(code plus OFF key), but the Keypad's low battery message display will
remain on as a reminder that you have a low battery condition in one or more
of your sensors. When you replace the weak battery with a fresh one, the
sensor will send a "good battery" signal to the control as soon as the sensor is
activated (opening/closing of door, window, etc.), causing the low battery
display to turn off. If the sensor is not activated, the display will
automatically clear within approximately 1 hour.
Routine Care
•
•
•
Treat the components of your security system as you would any other
electrical equipment. Do not slam sensor-protected doors or windows.
Keep dust from accumulating on the keypad and all protective sensors,
particularly on motion sensors and smoke detectors.
The keypad and sensors should be cleaned carefully with a dry soft cloth.
Do not spray water or any other fluid on the units.
– 68 –
Quick Guide to System Functions
FUNCTION
Check Zones
Display All
PROCEDURE
Press [✱].
Press and hold [✱] for 5 seconds.
COMMENTS
To view faulted zones when is system not ready
Displays all alpha descriptors programmed by
installer.
Descriptors
Arm System
Enter code.
Press arming key desired (AWAY,
STAY, INSTANT, MAXIMUM).
Arms system in mode selected.
NOTE: After pressing the STAY or INSTANT
arming key, enter 1, 2 or 3 to arm in
the desired STAY or INSTANT mode.
Disarms system and silences alarms.
Bypassed zones are unprotected and will not
cause an alarm if violated.
Disarm System
Bypass Zones
Enter code. Press OFF [1].
Enter code. Press BYPASS [6].
Enter zone numbers to be
bypassed (use 3-digit entries).
Enter code. Press BYPASS [6].
Press [#].
Enter code. Press BYPASS [6].
Press [✱]. Enter Group Number
(01-15)
Quick Bypass
Group Bypass
Bypasses all faulted zones automatically.
Bypasses all zones assigned to the group.
Chime Mode
Test Mode
Enter code. Press CHIME [9].
Keypad will sound if doors or windows are
violated while system disarmed.
Activates alarm sounder and allows sensors to
be tested.
Enter code. Press TEST [5]
View Messages
Press and hold [0] for at least 5
seconds.
Message from central station will appear.
View User
Capabilities
Enter user's code. Press [✱] + [✱].
Displays partitions & authority levels assigned
to the user.
GOTO Partition
Enter security code. Press [✱].
Enter partition number (1-8).
0 returns to default partition.
Allows a user at one keypad to perform
functions in another partition, if that user is
authorized to do so.
Self-Help
Press and hold any function key for Will display abbreviated instructions for the key
at least 5 seconds.
pressed.
Add a User
Enter master/manager code.
Press CODE [8].
Enter new user's user number.
Enter code for that user.
Enter authority for that user in this
partition (1-5).
Master & Manager level users can add users to
the system, each with its own code and
authority level.
Follow prompts, 1=Yes, 0=No.
Enter master/manager code.
Press CODE [8].
Change a User's
Code
Master & Manager level users can change their
own or other users' codes.
Enter user's 3-digit number.
Enter new code for that user.
Press 0 (No) at prompt.
– 69 –
Quick Guide to System Functions (cont’d)
FUNCTION
PROCEDURE
COMMENTS
Delete a User
Enter master/manager code.
Press CODE [8].
Enter user no. to be deleted.
Enter master/manager code.
Press 1 (Yes) at prompt.
Master & Manager level users can delete users.
A user can only be deleted by a user with higher
authority level.
Real-Time Clock
Press [✳] or [#] to move cursor. Enter time and
date accordingly. Press any key (0-9) for
AM/PM.
Enter Master code. Press
[63].
#
+
Control Output
Device
Activate output device as programmed.
Enter security code. Press
Enter 71 or 72.
#
#
#
#
#
Activate output device manually
Enter security code. Press
Enter 70.
Randomize
Output Device
Activate output device or system event instantly
Enter security code. Press
Enter 77.
Randomize output devices set for random
schedules
Enter security code. Press
Enter 41
Randomize output devices set for random
schedules with activation times between 6 PM
and 5 AM
Exit multi-partition multi-panel mode and multi-
panel view mode.
Enter security code. Press
Enter 42.
Enter 0.
Access Control
Enter security code. Enter 0.
Enter security code
Activate access relay for current partition.
Request to enter or exit at a console.
Press [#]. Enter 73.
Enter security code
Request to enter or exit at an access point.
Press [#]. Enter 74.
Enter access point number.
Change the access point state.
Enter security code. Press # .
Enter 75. Enter access point
number.
Enter state (1-3)
– 70 –
Summary of Audible Notification
(Alpha Display Keypads)
SOUND
LOUD,
CAUSE
FIRE ALARM
DISPLAY
FIRE is displayed; descriptor of zone in alarm is displayed.
INTERRUPTED*
Keypad & External
LOUD,
CONTINUOUS*
Keypad & External
ONE SHORT BEEP
(not repeated)
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM is displayed; descriptor of zone in alarm is also
displayed.
a. SYSTEM DISARM
a. DISARMED/READY TO ARM is displayed.
b. The number and descriptor of the open protection zone
is displayed.
c. Numbers and descriptors of the bypassed protection
zones are displayed (One beep is heard for each zone
displayed). Subsequently, the following is displayed:
DISARMED BYPASS Ready to Arm
b. SYSTEM ARMING ATTEMPT
WITH AN OPEN ZONE.
c. BYPASS VERIFY
Keypad only
ONE SHORT BEEP
(once every 15
sec.) Keypad only
TWO SHORT BEEPS
(once every 5 sec.)
Keypad only
SYSTEM IS IN TEST MODE
Opened Zone identifications will appear.
SYSTEM IS ABOUT TO
AUTOMATICALLY EXIT TEST
MODE
Opened Zone identifications will appear.
ONE BEEP
(every 60 sec.)
Keypad only
LOW BATTERY AT A
TRANSMITTER
LO BAT displayed with description of transmitter.
TWO SHORT BEEPS
Keypad only
ARM AWAY OR MAXIMUM
ARMED AWAY or ARMED MAXIMUM is displayed. Red
ARMED indicator is lit.
THREE SHORT
BEEPS
Keypad only
a. ARM STAY OR INSTANT
b. ZONE OPENED WHILE
SYSTEM IS IN CHIME MODE.
c. ENTRY WARNING**
a. ARMED STAY ZONE BYPASSED or ARMED
INSTANT ZONE BYPASSED is displayed. Red
ARMED indicator is lit.
b. CHIME displayed, descriptor of open protection zone
will be displayed if the [✱] key is pressed.
c. DISARM SYSTEM OR ALARM WILL OCCUR is
displayed.
RAPID BEEPING
Keypad only
a. TROUBLE
b. AC POWER LOSS ALERT***
c. MEMORY OF ALARM
a. CHECK displayed. Descriptor of troubled protection
zone is displayed.
b. AC LOSS displayed (may alternate with other displays
that may be present).
c. FIRE or ALARM is displayed; descriptor of zone in
alarm is displayed.
SLOW BEEPING
Keypad only
a. ENTRY DELAY WARNING**
b. EXIT DELAY WARNING
(if programmed)
a. DISARM SYSTEM OR ALARM WILL OCCUR is
displayed. Exceeding the delay time without disarming
causes alarm.
b. ARMED AWAY or ARMED MAXIMUM is displayed
along with You May Exit Now
*
If bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
** Entry warning may consist of three short beeps or slow continuous beeping, as programmed by your installer.
*** Loss of system battery power is not indicated or annunciated by the keypad (warnings are for loss of AC power
only).
– 71 –
FEDERAL COMMUNICATIONS COMMISSION STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
FCC CLASS B STATEMENT
This equipment has been tested to FCC requirements and has been found acceptable for use. The FCC
requires the following statement for your information:
This equipment generates and uses radio frequency energy and if not installed and used properly, that is, in
strict accordance with the manufacturer's instructions, may cause interference to radio and television
reception. It has been type tested and found to comply with the limits for a Class B computing device in
accordance with the specifications in Part 15 of FCC Rules, which are designed to provide reasonable
protection against such interference in a residential installation. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause interference to radio or
television reception, which can be determined by turning the equipment off and on, the user is encouraged
to try to correct the interference by one or more of the following measures:
• If using an indoor antenna, have a quality outdoor antenna installed.
• Reorient the receiving antenna until interference is reduced or eliminated.
• Move the radio or television receiver away from the receiver/control.
• Move the antenna leads away from any wire runs to the receiver/control.
• Plug the receiver/control into a different outlet so that it and the radio or television receiver are on different
branch circuits.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA CLASS B STATEMENT
ICES-003 Class B Notice - Avis NMB-003, Classe B
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
FCC/IC STATEMENT
This device complies with Part 15 of the FCC Rules, and RSS 210 of IC. Operation is subject to the
following two conditions: (1) This device may not cause harmful interference (2) This device must accept
any interference received, including interference that may cause undesired operation.
Cet appareil est conforme à la partie 15 des règles de la FCC & de RSS 210 des Industries Canada. Son
fonctionnement est soumis aux conditions suivantes: (1) Cet appareil ne doit pas causer d' interferences
nuisibles. (2) Cet appareil doit accepter toute interference reçue y compris les interferences causant une
reception indésirable.
IN THE EVENT OF TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X
(CA38A in Canada) telephone wall jack. We recommend that your certified installer demonstrate
disconnecting the phones on installation of the system. Do not disconnect the phone connection inside the
control/communicator. Doing so will result in the loss of your phone lines. If the regular phone works
correctly after the control/communicator has been disconnected from the phone lines, the
control/communicator has a problem and should be returned for repair. If upon disconnection of the
control/communicator, there is still a problem on the line, notify the telephone company that they have a
problem and request prompt repair service. The user may not under any circumstances (in or out of
warranty) attempt any service or repairs to the system. It must be returned to the factory or an authorized
service agency for all repairs.
– 72 –
“FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68 NOTICE
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a
label that contains, among other information, the FCC registration number and ringer equivalence
number (REN) for this equipment. If requested, this information must be provided to the
telephone company.
This equipment uses the following jacks:
An RJ31X is used to connect this equipment to the telephone network.
The REN is used to determine the quantity of devices which may be connected to the telephone
line. Excessive RENs on the telephone line may result in the devices not ringing in response to
an incoming call. In most, but not all areas, the sum of the RENs should not exceed five (5.0). To
be certain of the number of devices that may be connected to the line, as determined by the total
RENs, contact the telephone company to determine the maximum REN for the calling area.
If this equipment causes harm to the telephone network, the telephone company will notify you in
advance that temporary discontinuance of service may be required. If advance notice is not
practical, the telephone company will notify the customer as soon as possible. Also, you will be
advised of your right to file a complaint with the FCC if you believe necessary.
The telephone company may make changes in its facilities, equipment, operations, or procedures
that could affect the operation of the equipment. If this happens, the telephone company will
provide advance notice in order for you to make the necessary modifications in order to maintain
uninterrupted service.
If trouble is experienced with this equipment, please contact the manufacturer for repair and
warranty information. If the trouble is causing harm to the telephone network, the telephone
company may request you remove the equipment from the network until the problem is resolved.
There are no user serviceable components in this product, and all necessary repairs must be
made by the manufacturer. Other repair methods may invalidate the FCC registration on this
product.
This equipment cannot be used on telephone company-provided coin service. Connection to
Party Line Service is subject to state tariffs.
This equipment is hearing-aid compatible.
When programming or making test calls to an emergency number, briefly explain to the
dispatcher the reason for the call. Perform such activities in the off-peak hours; such as early
morning or late evening.
– 73 –
CANADIAN DEPARTMENT OF COMMUNICATIONS
(DOC) STATEMENT
NOTICE
AVIS
The Canadian Department of Communications label L’étiquette du ministère des Communications du Canada
identifies certified equipment. This certification means identifie le matériel homologué. Cette étiquette certifie que
that the equipment meets certain telecommunications le matériel est conforme à certaines normes de protection,
network
requirements. The Department does not guarantee the télécommunications. Le ministère n’assure toutefois pas
equipment will operate to the user’s satisfaction. que le matériel fonctionnera à la satisfaction de l’utilisateur.
protective,
operational
and
safety d’exploitation
et
de
sécurité
des
réseaux
de
Before installing this equipment, users should ensure Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il
that it is permissible to be connected to the facilities of est permis de le raccorder aux installations de l’entreprise
the local telecommunications company. The equipment locale de télécommunications. Le matériel doit également
must also be installed using an acceptable method of être installé en suivant une méthode acceptée de
connection. In some cases, the company’s inside wiring raccordement. Dans certains cas, les fils intérieurs de
associated with a single line individual service may be l’entreprise utilisés pour un service individuel à la ligne
extended by means of certified connector assembly unique peuvent être prolongés au moyen d’un dispositif
(telephone extension cord). The customer should be homologué de raccordement (cordon prolongateur
aware that compliance with the above conditions may téléphonique interne). L’abonné ne doit pas oublier qu’il est
not prevent degradation of service in some situations.
possible que la conformité aux conditions énoncées ci-
dessus n’empèchet pas la dégradation du service dans
certaines situations. Actuellement, les entreprises de
télécommunications ne permettent pas que l’on raccorde
leur matériel aux prises d’abonnés, sauf dans les cas precis
prévus par les tarifs particuliers de ces entreprises.
Repairs to certified equipment should be made by an
authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the
user to this equipment, or equipment malfunctions, may
give the telecommunications company cause to request
the user to disconnect the equipment.
Les réparations du matériel homologué doivent être
effectuées pas un centre d’entretien canadien autorisé
désigné par le fournisseur. La compagnie de
Users should ensure for their own protection that the
electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system,
if present, are connected together. This precaution may
be particularly important in rural areas.
télécommunications peut demander
à
l’utilisateur de
débrancher un appareil à la suite de réparations ou de
modifications effectuées par l’utilisateur ou à cause de
mauvais fonctionnement.
Caution: User should not attempt to make such
connections themselves, but should contact the
appropriate electric inspection authority, or electrician,
as appropriate.
Pour sa propre protection, l’utilisateur doit s’assurer que
tous les fils de mise en terre de la source d’énergie
électrique, des lignes téléphoniques de réseau de conduites
d’eau s’il
y
en a, soient raccordés ensemble. Cette
The Load Number (LN) assigned to each terminal
device denotes the percentage of the total load to be
connected to a telephone loop which is used by the
device, to prevent overloading. The termination on a
loop may consist of any combination of devices subject
only to the requirement that the total of the Load
Numbers of all the devices does not exceed 100.
précaution est particulièrement importante dans les régions
rurales.
Avertissement: L’utilisateur ne doit pas tenter de faire ces
raccordements lui-même; il doit avoir recours à un service
d’inspection des installations électriques, ou à un électricien,
selon le cas.
L’indice de charge (IC) assigné à chaque dispositif terminal
pour éviter toute surcharge indique le pourcentage de la
charge totale qui peut être raccordé
à
un circuit
téléphonique bouclé utilisé par ce dispositif. La terminaison
du circuit bouclé peut être constituée de n’importe quelle
combinaison de dispositifs, pourvu que la somme des
indices de charge de l’ensemble des dispositifs ne dépasse
pas 100.
– 74 –
WARNING!
THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or fire or
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a
variety of reasons. For example:
•
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor
or disconnect an alarm warning device.
•
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work
without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not put
in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however briefly.
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if
the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the
path.
•
•
•
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not
activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by the
Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this System
may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke detectors may
not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other
side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or building. A second
floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors have sensing
limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not always warn about
fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage
of flammable materials, overloaded electrical circuits, children playing with matches, or arson. Depending upon the nature
of the fire and/or the locations of the smoke detectors, the detector, even if it operates as anticipated, may not provide
sufficient warning to allow all occupants to escape in time to prevent injury or death.
•
•
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their installation
manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple beams of
protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot detect motion
or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or windows.
Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical
system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the
ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance can
decrease.
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the
other side of closed or partly open doors. If warning devices sound on a different level of the residence from the
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not
hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic.
Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service or
temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond
appropriately.
•
•
•
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to
last as long as 10 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.
This alarm system should be tested weekly to make sure all sensors and transmitters are working properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and
continue to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved
ones to learn about these developments.
– 75 –
Index
#70 Command .......................................46
4286 VIP Module ..............................9, 46
AC Loss..................................................62
Access Another Partition .....................22
Access Control Commands...................54
Access Door ...........................................45
Action Code ...........................................53
Action Specifier.....................................53
Add a User ............................................18
ADD NEW USER .................................20
Add User Code ......................................17
Alarm.......................................................6
Alkaline Batteries.................................66
Alpha Keypads......................................10
Arm/Disarm Commands.........................53
Armed......................................................7
ARMED INDICATOR ..........................13
Audible Emergency...............................42
Audible Signals.....................................70
Authority Level.....................................15
Authority Levels .............................16, 17
Auto-STAY Arming ..............................33
Away..................................................7, 22
AWAY....................................................39
AWAY Mode..........................................35
Battery Life...........................................66
Burglary ..................................................5
Burglary Protection................................7
Bypass- Access Door.............................45
Bypass Commands ...............................54
Bypass Zones.........................................29
Bypassing..............................................29
Call Service ...........................................61
Carbon Monoxide Protection..................6
Change a User's Code...........................20
Change User Code ................................17
CHECK..................................................61
Chime.................................................7, 40
Closing Time..........................................47
Comm. Failure ......................................61
Common Lobby......................................25
Delaying Closing Time..........................47
Delete a User.........................................21
Delete User Code...................................17
Descriptors ............................................28
Device Timers....................................8, 50
Disarm ...................................................38
DOC .......................................................73
Duress....................................................16
Duress Code...........................................15
Emergency...............................................5
Entry Delay ...........................................14
Entry/Exit................................................6
Exit Delay..............................................14
Exit User Edit Mode .............................17
Fire Alarm .............................................60
Fire.....................................................5, 42
Fire Protection ........................................6
GLOBAL ARM ......................................19
Global Arming.......................................22
Goto..................................................19, 22
GOTO Command.....................................8
Grant- Access Door ...............................45
Graphic/Touch-Screen Keypad.............34
Graphic/Touch-Screen Keypad.........5, 10
Group Bypass ........................................31
Honeywell Dealer..................................62
Instant ...............................................7, 22
INSTANT...............................................14
INSTANT Mode ....................................34
Keypad.....................................................5
Keypad Back Lighting ..........................10
Keypads .................................................10
Keyswitch ..............................................39
– 76 –
LO Bat ...................................................62
Low Battery...........................................66
Low Battery Warning...........................67
Macros .....................................................7
Manager.................................................16
Master....................................................16
Master Keypad..................................8, 23
Maximum ..........................................7, 22
MAXIMUM............................................14
MAXIMUM Mode..................................36
Memory of Alarm ..............................7, 38
Messages................................................41
Macro .....................................................43
Modem Comm .......................................62
MULTI-ACCESS...................................19
NFPA .....................................................63
Night......................................................34
Not Ready..............................................27
Off ..........................................................22
OFF........................................................38
Open Zones............................................27
Open/Close Schedules...........................47
Open/Close Windows ............................54
Operator A.............................................16
Operator B.............................................16
Operator C.............................................16
OUTPUT TIMER ..................................50
Panic Keys.............................................42
PANIC KEYS ........................................13
Partitioned System .................................6
Personal Emergency .............................42
Phone Access ...........................................9
Power .....................................................62
POWER/READY INDICATOR.............13
Protect- Access Door .............................45
Quick Arm .............................................13
Quick Arming........................................15
Quick Bypass.........................................30
Quick Exit..............................................37
Quick Guide.....................................68, 69
Randomize Output Devices..................52
Ready .................................................... 27
READY.................................................. 40
Ready Key............................................. 27
Real-Time Clock ................................... 69
Relay Commands .................................. 53
Relay Menu Mode................................. 46
Replacing Batteries.............................. 66
RF BUTTON......................................... 18
Routine Care......................................... 67
Schedules .......................................... 8, 47
Security Code........................................ 15
Security Codes...................................... 15
Sensing Devices...................................... 6
Silencing a Fire Alarm......................... 60
Silent Emergency ................................. 42
Smoke Detectors................................... 59
Speed Key ......................................... 7, 43
Stay ................................................... 7, 22
STAY..................................................... 39
STAY Mode........................................... 32
System LO Bat ..................................... 62
Temporary Schedules..................... 47, 48
Temporary Users.................................. 18
Test Key................................................ 59
Test Mode.............................................. 59
Testing Your System............................ 59
Time Window........................................ 47
TRBL..................................................... 61
Trouble Condition ................................ 61
Unable To Arm Lobby.......................... 25
User Edit Mode..................................... 17
User Numbers ...................................... 15
User's Instructions................................. 9
Using #77 Instant Activation Mode.... 53
Wireless Sensor .................................... 66
Zone Bypassed...................................... 32
Zone Descriptors................................... 28
Zones ....................................................... 6
– 77 –
TWO YEAR LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive, Melville,
New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal
wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a
proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at its
discretion, reflect the warranty period as commencing at invoice date. Except as required by law, this Limited Warranty is only made
to Buyer and may not be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at its sole
option and as the exclusive remedy hereunder, free of charge, any defective products.
Seller shall have no obligation under this Limited Warranty or otherwise if the product:
(i)
is improperly installed, applied or maintained;
(ii)
installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than the
Seller/Seller’s Authorized Service/Repair Center;
(iii)
(iv)
damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or the like;
or
defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes unrelated
to defective materials or workmanship, or failures related to batteries of any type used in connection with the products
sold hereunder.
Exceptions to Warranty With Respect to Honeywell Products listed below:
Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above limited
warranty for a period of five (5) years from the manufacture date code.
EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY
THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A
PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO
THE FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY (i)
CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN
ANY WAY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION,
EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE
IS CAUSED BY SELLER’S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE
POSSIBILITY OF SUCH LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Seller’s
agents), specifications, samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in connection with
the Buyer’s order are for the sole purpose of identifying the Seller’s products and shall not be construed as an express warranty or
condition. Any suggestions by Seller or Seller’s agents regarding use, applications, or suitability of the products shall not be construed
as an express warranty or condition unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells
may not be compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery,
fire or otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a properly
installed and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a
guarantee that such will not occur or will not cause or lead to personal injury or property loss. CONSEQUENTLY, SELLER SHALL
HAVE NO LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE OR OTHER LOSS BASED ON ANY CLAIM
AT ALL INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether
directly or indirectly for any loss or damage with respect to the products it sells, regardless of cause or origin, its maximum liability
shall not in any case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and
shall be the complete and exclusive remedy against the Seller. Should your product become defective during the warranty, please
contact your installer to facilitate repair or replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace
any defective product under warranty with new, refurbished, or remanufactured product.
– 78 –
NOTES
– 79 –
2 Corporate Center Drive, Suite 100
P.O. Box 9040, Melville, NY 11747
Copyright © 2010 Honeywell International Inc.
Ê800-06905EŠ
800-06905 6/10 Rev. C
|